Part number
C10N1TM040
Model no
NSX100N
466.67 SR On request Dispatch — · From TürkiyeGet a Quote

Schneider Electric C10N1TM040 ComPacT NSX100N 1P 40 A 25 kA at 240 V TM-D Fixed Moulded Case Circuit Breaker

Schneider Electric C10N1TM040 - ComPacT NSX100N 1P 40 A 25 kA TM-D moulded case circuit breaker.

Rated current
40 A
Rated operational voltage
277 V AC
Poles
1P
Description

About the NSX100N

The Schneider Electric C10N1TM040 is a 1P, 40 A ComPacT NSX100N moulded case circuit breaker fitted with a TM-D thermal-magnetic trip unit rated for 25 kA breaking capacity at 240 V AC. It carries a 277 V rated operational voltage and mounts on a fixed backplate, suited to distribution circuits sized to its 40 A nameplate rating.

Certifications & Standards

  • EN/IEC 60947-2

Selection Notes

The N frame sits at the mid tier of the ComPacT NSX100 breaking-capacity ladder (25 kA at 240 V AC), between the F (36 kA) and H (70 kA) frames of the same ComPacT NSX100 footprint. The TM-D trip unit on this C10N1TM040 variant has its thermal pickup fixed at 1x In, so the 40 A rating is the circuit's protected current with no field adjustment; choose the adjacent current rating in the same N frame if the protected load differs from 40 A.

Specification

Full specification

77 values · Last verified 30 Oct 2026

Main 20

Range ComPacT
Product name ComPacT NSX
Device short name NSX100N
Product or component type Circuit breaker
Device application Distribution
Poles description 1P
Protected poles description 1D
[In] rated current 40 A at 40 °C
[Ue] rated operational voltage 277 V AC 50/60 Hz, 250 V DC
Network type AC, DC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category A
Breaking capacity 25 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 250 V DC conforming to IEC 60947-2
Breaking capacity code N 25 kA 240 V AC
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit protection functions LI
Control type Toggle
Circuit breaker mounting mode Fixed

Complementary 23

[Ui] rated insulation voltage 750 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
[Ics] rated service breaking capacity 25 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 250 V DC conforming to IEC 60947-2
Mechanical durability 20000 cycles
Electrical durability 20000 cycles at 277 V In/2, 10000 cycles at 277 V In
Power dissipation per pole 5.47 W
Mounting support Backplate
Mounting position Horizontal and vertical, Flat on the back
Upside connection Front
Downside connection Front
Connection pitch 35 mm
Protection type L : for overload protection (thermal), I : for short-circuit protection (magnetic)
Trip unit rating 40 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection) Fixed
[Ir] long-time protection pick-up adjustment range 1 x In
Long-time protection delay adjustment type tr Fixed
Instantaneous protection pick-up adjustment type Ii Fixed
[Ii] instantaneous protection pick-up adjustment range 500 A
Earth-leakage protection Without
Width (W) 35 mm
Height (H) 161 mm
Depth (D) 86 mm
Net weight 0.7 kg

Environment 10

Standards EN/IEC 60947-2
Overvoltage category IV
Electrical shock protection class Class II on front face
Pollution degree 3 conforming to IEC 60664-1
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to IEC 62262
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -50…85 °C
Relative humidity 0…95 %
Operating altitude 0...2000 m without derating, 2000 m...5000 m with derating
Show all 77 specifications ↓ Show less ↑24 more values in Identification, Contractual warranty, Logistics.

Identification 7

Part number C10N1TM040
Type designation NSX100N
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production

Contractual warranty 1

Warranty (in months) 18

Logistics 16

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 4.000 cm
Package 1 Width 13.000 cm
Package 1 Length 17.500 cm
Package 1 Weight 737.200 g
Unit Type of Package 2 S03
Number of Units in Package 2 12
Package 2 Height 30.000 cm
Package 2 Width 30.000 cm
Package 2 Length 40.000 cm
Package 2 Weight 9.258 kg
Shipping weight 0.7 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for C10N1TM040

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • EN/IEC 60947-2
Quick answers

Questions about the NSX100N

What is the rated current of NSX100N?

The rated current of NSX100N is 40 A.

Which supply voltage is NSX100N rated for?

The rated operational voltage of NSX100N is 277 V AC.

What is the HS code of NSX100N for customs?

The tariff (HS) code on file for NSX100N is 85362090.

Where does NSX100N ship from, and how fast?

NSX100N ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for MCCB

All guides for MCCB
Reviews

Customer reviews

Series

Schneider Electric Schneider ComPacT NSX

Brand
Schneider Electric
Series
Schneider ComPacT NSX
Series page →
Series

Other series in Molded Case Circuit Breakers (MCCB)

466.67 SR On request
Get a Quote
Quote

Get a Quote

NSX100N

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · C10N1TM040

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart