Part number
C080N42EFM
7,961.05 SR On request Dispatch — · From TürkiyeGet a Quote

Schneider Electric C080N42EFM ComPacT NS800N 4P 800 A 50 kA MicroLogic 2.0 E Moulded Case Circuit Breaker

C080N42EFM – ComPacT NS800N 4P 800 A, 50 kA Icu at 380/415 V MCCB.

Rated current
800 A
Rated operational voltage
690 V AC
Poles
4P
Display
LCD display (Energy meter)
Description

About the C080N42EFM

The Schneider Electric C080N42EFM is a 4-pole ComPacT NS800N moulded case circuit breaker rated 800 A, with a 50 kA breaking capacity (Icu) at 380/415 V AC. It is fitted with a MicroLogic 2.0 E trip unit delivering long-time overload and instantaneous short-circuit protection (LI), is fixed-mounted and manually operated, and carries a 690 V rated operational voltage for industrial distribution switchboards.

Certifications & Standards

  • IECEE CB Scheme
  • EN/IEC 60947-2

Selection Notes

Its LI trip unit covers long-time overload and instantaneous short-circuit tripping only, which keeps the breaker simple and is adequate where upstream or downstream devices already handle short-time discrimination. The energy-meter display adds load energy tracking on top of the RMS current reading, useful for sub-metering a feeder. The N-frame rating gives it 50 kA Icu at 380/415 V AC, the standard distribution class for this amperage; step up to an H-frame sibling at the same 800 A when the prospective fault current at the installation point exceeds this breaker's Icu. The 4-pole version adds a switched or protected neutral, which is the variant to specify on a TT or IT system where the neutral itself needs disconnection or protection.

Specification

Full specification

80 values · Last verified 30 Oct 2026

Main 21

Range ComPacT
Product name ComPacT NS new generation
Range of product ComPacT NS630b...1600 new generation
Product or component type Circuit breaker
Device application Distribution
Number of poles 4P
Protected poles description 4D
Neutral position Left
[In] rated current 800 A at 50 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz
Network type AC
Network frequency 50/60 Hz
Suitability for isolation Yes conforming to EN/IEC 60947-2
Utilisation category Category B
Breaking capacity 85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 40 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2, 30 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code N 50 kA 415 V AC
Trip unit name MicroLogic 2.0 E
Trip unit technology Electronic
Trip unit protection functions LI
Control type Manually operated
Mounting mode Fixed

Complementary 31

[Ui] rated insulation voltage 800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947-2
[Ics] rated service breaking capacity 50 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2, 40 kA at 500/525 V AC 50/60 Hz conforming to IEC 60947-2, 30 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
[Icw] rated short-time withstand current 19.2 kA 1 s conforming to IEC 60947-2
Mechanical durability 10000 cycles
Electrical durability 2000 cycles at 690 V In, 4000 cycles at 690 V In/2, 5000 cycles at 440 V In, 6000 cycles at 440 V In/2
Power losses 15 W
Mounting support Backplate
Upside connection Front
Downside connection Front
Connection pitch 70 mm
Protection type L : for overload protection (long time), I : for instantaneous short-circuit protection
Trip unit rating 800 A at 50 °C
Long-time pick-up adjustment type Ir (thermal protection) Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range 0.4...1 x In
Long-time protection delay adjustment type tr Adjustable 9 settings
[tr] long-time delay adjustment range 12.5…600 s at 1.5 x Ir, 0.5…24 s at 6 x Ir, 0.7…16.6 s at 7.2 x Ir
Thermal memory 20 mn
Instantaneous protection pick-up adjustment type Ii Adjustable
[Ii] instantaneous protection pick-up adjustment range 1.5...10 x Ir
Earth-leakage protection Without
Neutral protection setting No protection (3D), 0.5 x Ir (3D + N/2), 1 x Ir (4D)
Zone selective interlocking ZSI Without
Auxiliary contact composition 1 NO/NC
Local signalling 4 LEDs (red) for fault indication, 1 LED (yellow) for overload
Display type LCD display
Type of measurement Energy meter
Width (W) 280 mm
Height (H) 327 mm
Depth (D) 147 mm
Net weight 18 kg

Environment 11

Standards EN/IEC 60947-2
Product certifications IECEE CB Scheme
Overvoltage category III
Electrical shock protection class Class II on front face
Pollution degree 3 conforming to IEC 60947
IP degree of protection IP40 conforming to IEC 60529
IK degree of protection IK07 conforming to EN 50102
Ambient air temperature for operation -25…70 °C
Ambient air temperature for storage -40…85 °C
Relative humidity 0…95 %
Operating altitude 0...2000 m without derating, 2000 m...5000 m with derating
Show all 80 specifications ↓ Show less ↑17 more values in Identification, Contractual warranty, Logistics.

Identification 6

Part number C080N42EFM
Brand Schneider Electric
Condition New, factory sealed
Source Schneider Electric and its authorised distributors
Warranty Manufacturer warranty
Lifecycle status Active, in production

Contractual warranty 1

Warranty (in months) 18

Logistics 10

Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 30.000 cm
Package 1 Width 40.000 cm
Package 1 Length 60.000 cm
Package 1 Weight 15.800 kg
Shipping weight 18.0 kg
Ships from Türkiye
Dispatch —
Stock On request

Source: manufacturer data · Last verified: 30 Oct 2026

Documents

Documents for C080N42EFM

No documents are on file for this part yet.

Ask us for the datasheet
Certifications

Certifications and standards

  • CB Scheme
  • EN/IEC 60947-2
Quick answers

Questions about the C080N42EFM

What is the rated current of C080N42EFM?

The rated current of C080N42EFM is 800 A.

Which supply voltage is C080N42EFM rated for?

The rated operational voltage of C080N42EFM is 690 V AC.

What is the HS code of C080N42EFM for customs?

The tariff (HS) code on file for C080N42EFM is 85362090.

Where does C080N42EFM ship from, and how fast?

C080N42EFM ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.

Guides

Guides for MCCB

All guides for MCCB
Reviews

Customer reviews

Series

Schneider Electric Schneider ComPacT NS

Brand
Schneider Electric
Series
Schneider ComPacT NS
Series page →
Series

Other series in Molded Case Circuit Breakers (MCCB)

7,961.05 SR On request
Get a Quote
Quote

Get a Quote

Genuine parts

Genuine, factory-sealed parts

Schneider Electric · C080N42EFM

Every part on Stoklink is new, unused and made by the manufacturer named on the page.

Condition
New and unused, in the manufacturer's factory-sealed packaging.
Sourced from
Schneider Electric and its authorised distributors.
Warranty
The manufacturer's warranty applies.
If a part is not genuine
We refund the full amount.

Added to cart Could not add to cart

View cart