ABB S200 vs S800: Standard vs High-Performance MCB
ABB S200 and S800 MCBs compared on current rating, breaking capacity, standards, and the point where a feeder outgrows S200 and needs S800.
The Schneider Electric A9N61533 is a 2-pole, 25 A, C-curve DC miniature circuit breaker from the Acti9 C60H-DC range, rated for 500 V DC operational voltage. Its thermal-magnetic trip unit covers overload and short-circuit protection, it is suitable for isolation to IEC/EN 60947-2, and it breaks 20 kA at 220-250 V DC or 6 kA at 500 V DC in a 36 mm DIN-rail body.
The A9N61533 carries its 25 A rating at a 25 °C reference, so in a sealed DC enclosure running warmer than that the usable continuous current falls; when the steady load already sits close to 25 A, the 32 A variant of the same C60H-DC frame is the safer pick. Breaking capacity depends on how high the DC bus voltage is: 20 kA Icu at 220-250 V DC, but only 10 kA at 440 V DC and 6 kA at 500 V DC, so check the prospective fault current of the battery bank or rectifier against the voltage you actually run before specifying it. With two protected poles, the positive and negative conductors are both opened and isolated, which suits floating or unearthed DC systems where either conductor can carry fault current. The C curve tolerates the moderate switch-on current of DC power supplies and small DC motors without nuisance tripping, while a B-curve breaker is the closer match for long cable runs with low fault levels.
| Range | Acti9 |
|---|---|
| Product name | Acti9 C60H-DC |
| Product or component type | Miniature circuit-breaker |
| Device short name | C60H-DC |
| Device application | Distribution |
| Poles description | 2P |
| Number of protected poles | 2 |
| [In] rated current | 25 A at 25 °C |
| Network type | DC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 10 kA Icu at 440 V DC conforming to EN 60947-2, 10 kA Icu at 440 V DC conforming to IEC 60947-2, 6 kA Icu at 500 V DC conforming to EN 60947-2, 6 kA Icu at 500 V DC conforming to IEC 60947-2, 20 kA Icu at 220 V DC conforming to GB 14048.2, 20 kA Icu at 220 V DC conforming to IEC 60947-2, 20 kA Icu at 250 V DC conforming to GB 14048.2, 20 kA Icu at 250 V DC conforming to IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2, Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-2, Yes conforming to EN 60947-2 |
| Standards | EN 60947-2, IEC 60947-2 |
| Network frequency | 50/60 Hz |
|---|---|
| [Ue] rated operational voltage | 500 V DC |
| [Ics] rated service breaking capacity | 15 kA 75 % conforming to EN 60947-2 - 220 V DC, 15 kA 75 % conforming to IEC 60947-2 - 220 V DC, 15 kA 75 % conforming to EN 60947-2 - 250 V DC, 15 kA 75 % conforming to IEC 60947-2 - 250 V DC, 4.5 kA 75 % conforming to EN 60947-2 - 500 V DC, 4.5 kA 75 % conforming to IEC 60947-2 - 500 V DC, 7.5 kA 75 % conforming to EN 60947-2 - 440 V DC, 7.5 kA 75 % conforming to IEC 60947-2 - 440 V DC |
| [Ui] rated insulation voltage | 500 V DC conforming to IEC 60947-2, 500 V DC conforming to EN 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-2, 6 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| Local signalling | ON/OFF indication |
| Mounting mode | Fixed |
| Mounting support | 35 mm symmetrical DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: standard |
| 9 mm pitches | 4 |
| Net weight | 0.256 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 3000 cycles L/R = 2 ms |
| Provision for padlocking | Padlockable |
| Locking options description | In position O |
| Tightening torque | Power circuit: 2.5 N.m top or bottom |
| Earth-leakage protection | Without |
| Pollution degree | 3 conforming to EN 60947-2, 3 conforming to IEC 60947-2 |
|---|---|
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-2 |
| Operating altitude | 2000 m |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Part number | A9N61533 |
|---|---|
| Type designation | C60H-DC |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| Warranty (in months) | 18 |
|---|
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.500 cm |
| Package 1 Width | 3.700 cm |
| Package 1 Length | 8.500 cm |
| Package 1 Weight | 233.000 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 8.400 cm |
| Package 2 Width | 9.200 cm |
| Package 2 Length | 22.500 cm |
| Package 2 Weight | 1.449 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 72 |
| Package 3 Height | 30.000 cm |
| Package 3 Width | 30.000 cm |
| Package 3 Length | 40.000 cm |
| Package 3 Weight | 17.938 kg |
| Shipping weight | 0.256 kg |
| Ships from | Türkiye |
| Dispatch | 29 Dec |
| Stock | Low stock |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of C60H-DC is 25 A.
The tariff (HS) code on file for C60H-DC is 853620.
C60H-DC ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 30 business days.
ABB S200 and S800 MCBs compared on current rating, breaking capacity, standards, and the point where a feeder outgrows S200 and needs S800.
A grounded, spec-by-spec comparison of Schneider Acti9 iC60, ABB S200 and Siemens 5SY miniature circuit breakers covering curve availability, breaking-capacity tiers, RCBO options and...
A load-by-load walkthrough matching MCB tripping curves B, C, D, K, and Z to inrush current so the breaker neither nuisance-trips nor under-protects the...