ABB S200 vs S800: Standard vs High-Performance MCB
ABB S200 and S800 MCBs compared on current rating, breaking capacity, standards, and the point where a feeder outgrows S200 and needs S800.
The Schneider Electric A9F74325 is an iC60N series 3-pole 25A miniature circuit breaker (MCB) designed for reliable overload and short-circuit protection in residential, commercial, and light industrial DIN rail installations. The A9F74325 delivers robust modular protection in a compact form factor, making it ideal for distribution boards and panel-building applications where space efficiency and dependable tripping performance are essential.
| Range | Acti9 |
|---|---|
| Product name | Acti9 iC60 |
| Product or component type | Miniature circuit-breaker |
| Device short name | IC60N |
| Device application | Distribution |
| Poles description | 3P |
| Number of protected poles | 3 |
| [In] rated current | 25 A |
| Network type | DC, AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Product compatibility | Vigi iC60 single terminal add-on residual current device 25/40/63 A, Quick Vigi iC60 single terminal add-on residual current device 25/40 A |
| Utilisation category | Category A conforming to EN/IEC 60947-2 |
| Suitability for isolation | Yes conforming to EN/IEC 60898-1, Yes conforming to EN/IEC 60947-2 |
| Standards | EN/IEC 60947-2, EN/IEC 60898-1 |
| Network frequency | 50/60 Hz |
|---|---|
| [Ue] rated operational voltage | 12...133 V AC 50/60 Hz, 220...240 V AC 50/60 Hz, 380...415 V AC 50/60 Hz, 440 V AC 50/60 Hz, <= 180 V DC |
| Magnetic tripping limit | 8 x In +/- 20 % |
| Breaking capacity | 36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2, 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2, 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2, 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2, 10 kA Icu at <= 180 V DC conforming to EN/IEC 60947-2, 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 |
| [Ics] rated service breaking capacity | 27 kA 75 % x Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2, 15 kA 75 % x Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2, 7.5 kA 75 % x Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2, 4.5 kA 75 % x Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2, 10 kA 100 % x Icu at <= 180 V DC conforming to EN/IEC 60947-2 |
| Limitation class | 3 conforming to EN/IEC 60898-1 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| Local signalling | Trip indicator |
| Mounting mode | Clip-on, Removable comb busbar installed |
| Mounting support | 35 mm DIN rail |
| Comb busbar and distribution block compatibility | Top or bottom: YES |
| Connection pitch | 18 mm between phases |
| 9 mm pitches | 6 |
| Height | 85 mm |
| Width | 54 mm |
| Depth | 78.5 mm |
| Net weight | 0.375 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles |
| Connections - terminals | Single terminal (top or bottom) , for 1 cable(s) , 1…25 mm², rigid, copper, Single terminal (top or bottom) , for 1 cable(s) , 1…16 mm², flexible, copper, Single terminal (top or bottom) , for 1 cable(s) , 1…16 mm², flexible with ferrule, copper, Single terminal (top or bottom) , for 1.0 cable(s) , flexible, copper or aluminium, with ring terminal and accessory |
| Wire stripping length | 14 mm for top or bottom connection |
| Tightening torque | 2 N.m top or bottom |
| Earth-leakage protection | Separate block |
| IP degree of protection | IP20 conforming to IEC 60529, IP40 in modular enclosure (Insulation class II) conforming to IEC 60529 |
|---|---|
| Pollution degree | 3 conforming to EN/IEC 60947-2 |
| Overvoltage category | IV |
| Tropicalisation | 2 conforming to IEC 60068-1 |
| Relative humidity | 95 % at 55 °C |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -35…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Part number | A9F74325 |
|---|---|
| Type designation | IC60N |
| Brand | Schneider Electric |
| Condition | New, factory sealed |
| Source | Schneider Electric and its authorised distributors |
| Warranty | Manufacturer warranty |
| Lifecycle status | Active, in production |
| Warranty (in months) | 18 |
|---|
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 7.500 cm |
| Package 1 Width | 5.500 cm |
| Package 1 Length | 9.500 cm |
| Package 1 Weight | 343.900 g |
| Unit Type of Package 2 | BB1 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 8.000 cm |
| Package 2 Width | 9.500 cm |
| Package 2 Length | 22.500 cm |
| Package 2 Weight | 1.442 kg |
| Unit Type of Package 3 | S03 |
| Number of Units in Package 3 | 44 |
| Package 3 Height | 30 cm |
| Package 3 Width | 30 cm |
| Package 3 Length | 40 cm |
| Package 3 Weight | 16.349 kg |
| Shipping weight | 0.375 kg |
| Ships from | Türkiye |
| Dispatch | 16 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of IC60N is 25 A.
The tariff (HS) code on file for IC60N is 853620.
IC60N ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
ABB S200 and S800 MCBs compared on current rating, breaking capacity, standards, and the point where a feeder outgrows S200 and needs S800.
A grounded, spec-by-spec comparison of Schneider Acti9 iC60, ABB S200 and Siemens 5SY miniature circuit breakers covering curve availability, breaking-capacity tiers, RCBO options and...
A load-by-load walkthrough matching MCB tripping curves B, C, D, K, and Z to inrush current so the breaker neither nuisance-trips nor under-protects the...