The ABB 2CSB203001R1250 (DDA203 AC-25/0.03) is a 3-pole, 25 A residual current device block with 30 mA Type AC sensitivity and instantaneous tripping, designed to add earth-fault protection to S200-series and S300P miniature circuit breakers. It is rated 230/400 V with a 1 kA short-circuit current rating and mounts on 5 DIN-rail module spacings.
The AC-25/0.03 suffix on the DDA203 encodes 25 A rated current and 30 mA sensitivity, the stricter setting used for direct-contact protection on 3-phase circuits. As a 3-pole block it protects all three phases of a 3-phase MCB rather than the single-phase coverage of a 2-pole RCD block. Choose the 300 mA sensitivity version instead where only indirect-contact protection is needed.
| Type of Residual Current | Type AC |
|---|---|
| Test Voltage (Ut) | 195...440 V |
| Rated Current Sensitivity | 30 mA |
| Leakage Current Type | AC |
| Power Supply Connection | Arbitrary |
| Electrical Endurance | 10000 cycle |
| Number of Poles | 3P |
| Number of Modular Spacings per DIN Rail | 5 |
| Operating Characteristic | Instantaneous |
| Tightening Torque | 1.2 N·m |
| Cable Cross-Section | Flexible Cable 0...16 mm², Rigid Cable 0...16 mm² |
| Connecting Capacity | Flexible 0...16 mm², Rigid Cable 0...16 mm² |
| Short-Circuit Current Rating (SCCR) UL/CSA | 1 kA |
|---|---|
| Rated Voltage (Ur) | 230/400 V |
| Rated Operational Voltage | 230/400 V |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 500 V |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Rated Current (In) | 25 A |
| Rated Residual Current | 30 mA |
| Rated Frequency (f) | 50 / 60 Hz |
| Power Loss | Total 3 W |
| Number of Modules | 5 |
|---|
| Part number | 2CSB203001R1250 |
|---|---|
| Type designation | DDA203 |
| Brand | ABB |
| Condition | New, factory sealed |
| Source | ABB and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 8012542792505 |
| ETIM class | EC002297 |
| eCl@ss | 27142210 |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 212 g |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
|---|---|
| RoHS Date | 20070731 |
| REACH Information | True - contains substances > 0.1 mass percentage |
| REACH Date | 20251223 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Consumer |
| Ambient Temperature | -25...55 °C |
|---|---|
| Ambient Air Temperature | Operation -25...50 °C |
| Degree of Protection | IP2X |
| Pollution Degree | 2 |
| Resistance to Vibrations | 20 Cycles with Load 0.8 In: 1g or 0.1mm 5...150...5 Hz |
| Resistance to Shock acc. to IEC 60068-2-27 | 25g 2 shocks 13 ms |
| Environmental Information | Refer to RoHS |
| Product Net Width | 87.5 mm |
|---|---|
| Product Net Height | 93 mm |
| Product Net Depth / Length | 69 mm |
| Product Net Weight | 325 g |
| ETIM 10 | EC002297 - Residual current circuit breaker (RCCB) module |
|---|---|
| UNSPSC | 39121601 |
| eClass | V11.0 : 27142210 |
| Standards | IEC/EN 61009 Ann. G |
| Shipping weight | 0.325 kg |
|---|---|
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 02 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of DDA203 is 25 A.
The rated operational voltage of DDA203 is 230–400 V AC.
The tariff (HS) code on file for DDA203 is 853630.
The EAN (GTIN) of DDA203 is 8012542792505.
DDA203 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
A step-by-step checklist for selecting RCD sensitivity, type, poles and rated current, matched to the earthing system, IEC standards, and special cases like EV...
How S-type selective RCDs coordinate with downstream instantaneous devices using the 2x current ratio and time-delay rule from IEC 60947-2 and IEC 61008-1.
Type A RCDs resolve AC and pulsating DC, while Type B is required wherever a fault can produce smooth DC, covering three-phase VFDs, most...