ABB S200 vs S800: Standard vs High-Performance MCB
ABB S200 and S800 MCBs compared on current rating, breaking capacity, standards, and the point where a feeder outgrows S200 and needs S800.
ABB S800-UVR130 110-130 V AC/DC undervoltage release accessory for S800 high performance circuit breakers.
Rated for 110-130 V AC/DC control circuits, the ABB 2CCS800900R0261 S800-UVR130 is an undervoltage release accessory that automatically opens a compatible S800 high performance circuit breaker if its control supply voltage collapses or is deliberately removed. This gives panels built around 110-130 V control transformers a fail-safe trip path that does not depend on the breaker's own overcurrent protection.
The 2CCS800900R0261 is an undervoltage release rated for 110-130 V AC/DC control circuits, matching the single-phase control transformers common on 110-130 V panels. Because it trips the breaker automatically when control voltage collapses or is deliberately removed, it gives a fail-safe no-volt trip path that operates independently of the breaker's own overcurrent protection. Panels built around a different control voltage need the UVR version matched to that voltage; mounting this 110-130 V unit on a 24 V or 220-250 V control circuit would prevent it from resetting or holding in.
| Suitable For | S800P, S800S, S800N, S800C, S800B, S800HV, S800U, S800PV-SP, S800PV-SD, S800PV-M-H |
|---|
| Rated Voltage (Ur) | 110 ... 130 V |
|---|---|
| Rated Operational Voltage | 110 ... 130 V |
| Rated Control Supply Voltage (Us) | (50 Hz) 130...130 V, (50 Hz) 130...130 V, (60 Hz) 130...130 V, (60 Hz) 130...130 V, (DC) 130...130 V, (DC) 130...130 V |
| Frequency (f) | 50/60 Hz |
| Power Loss | Total 1.3 ... 1.41 W, Total 1.4 V·A |
| Number of Contacts CO | 0 |
| Number of Contacts NC | 0 |
| Number of Contacts NO | 0 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
|---|---|
| RoHS Date | 20190320 |
| REACH Information | False - does not contain substances > 0.1 mass percentage |
| REACH Date | 20250313 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Business |
| Part number | 2CCS800900R0261 |
|---|---|
| Type designation | S800-UVR130 |
| Brand | ABB |
| Condition | New, factory sealed |
| Source | ABB and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 7612271208387 |
| ETIM class | EC001022 |
| eCl@ss | 27370417 |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 170 g |
| Product Net Width | 27 mm |
|---|---|
| Product Net Height | 95 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 150 g |
| EPLAN Data | 9AAC212941_EPLAN |
|---|
| ETIM 10 | EC001022 - Under voltage coil |
|---|---|
| UNSPSC | 39121010 |
| eClass | V11.0 : 27370417 |
| Standards | IEC 60947-5-1_UL489 |
| Shipping weight | 0.15 kg |
|---|---|
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 02 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe tariff (HS) code on file for S800-UVR130 is 853890.
The EAN (GTIN) of S800-UVR130 is 7612271208387.
S800-UVR130 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
ABB S200 and S800 MCBs compared on current rating, breaking capacity, standards, and the point where a feeder outgrows S200 and needs S800.
A grounded, spec-by-spec comparison of Schneider Acti9 iC60, ABB S200 and Siemens 5SY miniature circuit breakers covering curve availability, breaking-capacity tiers, RCBO options and...
A load-by-load walkthrough matching MCB tripping curves B, C, D, K, and Z to inrush current so the breaker neither nuisance-trips nor under-protects the...