ABB AF Series vs Schneider TeSys Contactor: Full Technical Comparison
ABB AF contactor vs Schneider TeSys: full technical comparison of coil tech, ratings, coordination, and selection for IEC motor starters. Shop at Stoklink.
The ABB AF265-30-11-11 is a 3-pole AC power contactor rated at 400 A (AC-1) and up to 1000 V IEC, designed for heavy-duty industrial motor switching and load control applications. Catalog number AF265-30-11-11 (SKU 1SFL547002R1111) belongs to ABB's AF series and delivers 132 kW at 400 V AC-3, making it an ideal choice for demanding automation and control panel installations worldwide.
| Product Net Width | 140 mm |
|---|---|
| Product Net Depth / Length | 180 mm |
| Product Net Height | 225 mm |
| Product Net Weight | 3.9 kg |
| Number of Main Contacts NO | 3 |
|---|---|
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 350 A, (1000 V) 55 °C 300 A, (1000 V) 60 °C 300 A, (1000 V) 70 °C 240 A, (690 V) 40 °C 400 A, (690 V) 55 °C 350 A, (690 V) 70 °C 290 A |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 265 A, (440 V) 55 °C 265 A, (500 V) 55 °C 250 A, (690 V) 55 °C 250 A, (1000 V) 55 °C 113 A, (380 / 400 V) 55 °C 265 A, (220 / 230 / 240 V) 55 °C 265 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 2 Poles in Series, 40 °C 350 A, (220 V) 3 Poles in Series, 40 °C 350 A |
| Rated Operational Current DC-3 (Ie) | (110 V) 2 Poles in Series, 40 °C 350 A, (220 V) 3 Poles in Series, 40 °C 350 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 2 Poles in Series, 40 °C 350 A, (220 V) 3 Poles in Series, 40 °C 350 A |
| Rated Operational Power AC-3 (Pe) | (415 V) 132 kW, (440 V) 160 kW, (500 V) 160 kW, (690 V) 200 kW, (1000 V) 160 kW, (380 / 400 V) 132 kW, (220 / 230 / 240 V) 75 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Breaking Capacity AC-3e | 8.5 x Ie AC-3e |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Rated Making Capacity AC-3e | 12 x Ie AC-3e |
| Short-Circuit Protective Devices | gG Type Fuses 500 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1224 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2650 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2120 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 865 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3800 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3300 A |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 300 cycles per hour |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 24 ... 60 V, 60 Hz 24 ... 60 V, DC Operation 20 ... 60 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 10.5 V·A, Holding at Max. Rated Control Circuit Voltage 50 Hz 2.8 W, Holding at Max. Rated Control Circuit Voltage 60 Hz 10.5 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 2.8 W, Holding at Max. Rated Control Circuit Voltage DC 3 W, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 903 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 903 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 1029 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 1029 W |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 20 W, at Rated Operating Conditions AC-3 per Pole 9 W |
| Operate Time | Between Coil De-energization and NO Contact Opening 37 ... 47 ms, Between Coil Energization and NO Contact Closing 25 ... 55 ms |
| Connecting Capacity Main Circuit | Flexible 2 x 70 ... 185 mm², Rigid Al-Cable 1 x 185 ... 240 mm², Rigid Cu-Cable 2 x 70 ... 185 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 1 x 1 .... 4 mm², Stranded 2 x 1 .... 4 mm² |
| Connecting Capacity | Flexible 2 x 70 ... 185 mm², Rigid Al-Cable 1 x 185 ... 240 mm², Rigid Cu-Cable 2 x 70 ... 185 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Tightening Torque | Cable Lug 9 N·m, Main Circuit 22 ... 43 N·m |
| Terminal Type | Main Circuit: Bars |
| Product Name | Block Contactor |
| NEMA Size | 5 |
|---|---|
| Continuous Current Rating NEMA | 270 A |
| Horsepower Rating NEMA | (200 V AC) Three Phase 75 Hp, (230 V AC) Three Phase 100 Hp, (460 V AC) Three Phase 200 Hp, (575 V AC) Three Phase 200 Hp |
| Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
| General Use Rating UL/CSA | (1000 V AC) 300 A, (600 V AC) 350 A |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 75 hp, (208 V AC) Three Phase 75 hp, (220 ... 240 V AC) Three Phase 100, (440 ... 480 V AC) Three Phase 200 hp, (550 ... 600 V AC) Three Phase 250 hp |
| Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 240 A, (550 ... 600 V AC) Three Phase 242 A |
| Part number | 1SFL547002R1111 |
|---|---|
| Type designation | AF265-30-11-11 |
| Brand | ABB |
| Condition | New, factory sealed |
| Source | ABB and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 7320500481141 |
| eCl@ss | 27371003 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C, Close to Contactor for Storage -40 ... 70 °C |
|---|---|
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| REACH Declaration | 2CMT2021-006202 |
|---|---|
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | eccbb2ba-8b36-4041-9c4c-9678da17730a China |
| Simplified SCIP | 15f68372-9a63-423a-9059-3665e303bdd2 Bulgaria, 1cfc9918-3626-4948-a01b-d30ecd42da7a Finland, 293a52cd-ccf1-4ee8-896d-3c61bbee0b34 Portugal, 49184298-1e5d-426c-8887-754eba614d46 Greece, 4c0ecce7-f01a-42e2-82a7-dbb225f9910d Estonia, 57b929f7-b9ad-44e1-94b6-7067d013e7e7 Hungary, 5a9f7b8a-5d12-4755-bf57-5aba2c2b41aa Romania, 60680253-057d-4af6-950b-485e529a371e Croatia, 678055ef-156d-4237-8c00-5287af574275 Poland, 71783d07-3f3e-42f3-9ada-43339d1e3792 Czechia, 88ebb685-e4ab-4aa8-b85b-48dc71b80176 Netherlands, 8d7b0d60-9ce1-430a-8d56-3301afc8f5ed Sweden, adedfd99-92c3-470f-941b-7dea49714686 Spain, bac3fe07-f844-43e8-b22b-fee289ece729 Germany, c233ff84-f75c-48a7-a3bb-3f738b6f862c Norway, c800d6d1-ac8a-43e3-8b02-c77809bf2cf7 Belgium, e058cf29-735f-4904-ade6-af9619c46869 Denmark, f342a6ec-a761-49eb-8e28-1d34b44de230 France |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ETIM 7 | EC000066 - Power contactor, AC switching |
|---|---|
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| E-Number (Sweden) | 3210153 |
| Package Level 1 Units | box 1 piece |
|---|---|
| Package Level 1 Width | 263 mm |
| Package Level 1 Depth / Length | 203 mm |
| Package Level 1 Height | 289 mm |
| Package Level 1 Gross Weight | 4.6 kg |
| Package Level 1 EAN | 7320500481141 |
| Shipping weight | 4.6 kg |
| Ships from | Türkiye |
| Dispatch | 16 Nov |
| Stock | In stock |
Source: manufacturer data · Last verified: 30 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of AF265-30-11-11 is 400 A.
The rated operational voltage of AF265-30-11-11 is 1000 V AC.
The rated motor power of AF265-30-11-11 is 132 kW.
The tariff (HS) code on file for AF265-30-11-11 is 85364900.
The EAN (GTIN) of AF265-30-11-11 is 7320500481141.
AF265-30-11-11 ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival. Stock items are dispatched within 1–2 business days.
ABB AF contactor vs Schneider TeSys: full technical comparison of coil tech, ratings, coordination, and selection for IEC motor starters. Shop at Stoklink.
AC-1 and AC-6a contactors for data center PDU and UPS systems: sizing, harmonic derating, coil selection, and endurance guidance for engineers. Shop at Stoklink.
Compare AC3 rating IEC contactors versus NEMA size codes, with cross-reference tables, derating formulas, and selection tips for engineers. Shop at Stoklink.