Monitoring Relays for Generators and ATS Systems
How phase-sequence, voltage/frequency and temperature monitoring relays let an ATS safely transfer a load onto a standby generator and back.
Carrying catalog designation OXB500E3X3QB, the ABB 1SCA151744R1001 is a 500 A TruONE automatic transfer switch rated for 3-pole, two-source switching duty at 200-480 V AC. A Level 3 LCD controller manages the delayed I-O-II transition, and the open-style unit carries a 42 kA Icw short-time withstand rating with bottom-fed line terminals.
The 3-pole configuration switches only the phase conductors and leaves the neutral solid, which fits three-wire distribution or installations where the neutral is bonded elsewhere and does not need to follow the transfer; pick the 4-pole (S) version instead when the system requires the neutral to open with the phases. The Level 3 controller adds a built-in LCD for on-device transfer-parameter setup and status readout, useful where a technician needs to confirm settings without a separate laptop or HMI. Bottom-fed line terminals (QB) suit panels wired with incoming supply below the switch; pick the QT variant instead when busbars feed in from above. For higher continuous-current duty, the 630 A frame in the same OXB TruONE range covers loads this 500 A unit does not.
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
|---|
| Degree of Protection | Front IP20 |
|---|---|
| Pollution Degree | 3 |
| Product Net Width | 447 mm, 17.6 in |
|---|---|
| Product Net Height | 313 mm, 12.32 in |
| Product Net Depth / Length | 212 mm, 8.35 in |
| Product Net Weight | 19.12 kg, 42.15 lb |
| Part number | 1SCA151744R1001 |
|---|---|
| Type designation | OXB500E3X3QB |
| Brand | ABB |
| Condition | New, factory sealed |
| Source | ABB and its authorised distributors |
| Warranty | Manufacturer warranty |
| EAN | 6417019822655 |
| ETIM class | EC000216 |
| eCl@ss | 27371403 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Controller Type | Level 3 (LCD) |
|---|---|
| Conventional Free-air Thermal Current (Ith) | Θ = 40 °C 500 A |
| Handle Type | Direct Mount |
| Number of Poles | 3P |
| Position of Line Terminals | Supplies on Bottom - Load on Top |
| Power Loss | at Rated Operating Conditions per Pole 17.2 W, Total 51.6 W |
| Rated Frequency (f) | Main Circuit 50-60 Hz |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current AC-31B (Ie) | (200 … 415 V AC) 500 A |
| Rated Operational Current AC-32B (Ie) | (200 … 415 V AC) 500 A |
| Rated Operational Current AC-33B (Ie) | (200 … 415 V AC) 500 A |
| Rated Operational Voltage | Main Circuit 200...480 V AC |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 0.1 s 42 kiloampere rms |
| Special Functions | Open style |
| Standards | IEC60947-6-1 |
| Terminal Type | Bolt |
| Transition Type | Delayed |
| ETIM 10 | EC000216 - Switch disconnector (AC) |
|---|---|
| eClass | V11.1 : 27371403 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Package Level 1 Units | box 1 piece |
|---|---|
| Package Level 1 Width | 345 mm, 13.58 in |
| Package Level 1 Depth / Length | 565 mm, 22.24 in |
| Package Level 1 Height | 240 mm, 9.45 in |
| Package Level 1 Gross Weight | 19.92 kg, 43.92 lb |
| Package Level 1 EAN | 6417019822655 |
| Shipping weight | 19.12 kg |
| Ships from | Türkiye |
| Dispatch | — |
| Stock | On request |
Source: manufacturer data · Last verified: 02 Oct 2026
No documents are on file for this part yet.
Ask us for the datasheetThe rated current of OXB500E3X3QB is 500 A.
The rated operational voltage of OXB500E3X3QB is 200–480 V AC.
The tariff (HS) code on file for OXB500E3X3QB is 853650.
The EAN (GTIN) of OXB500E3X3QB is 6417019822655.
OXB500E3X3QB ships from Türkiye. Shipping calculated at checkout · import duties and taxes paid on arrival.
How phase-sequence, voltage/frequency and temperature monitoring relays let an ATS safely transfer a load onto a standby generator and back.