Power Supplies
293 parts 3 sub-families
Power supplies from Siemens, Schneider Electric and ABB, with over 290 products that convert AC mains to stabilized 24 V DC for control circuits, PLCs and field devices. The range includes SITOP and Modicon DIN rail units, DC UPS and buffer modules, and redundancy and DC converter modules. Stoklink ships worldwide from Turkey and quotes project quantities on request.
3 sub-families of Power Supplies
-
207 parts
DIN Rail Power Supplies (24V DC)
DIN rail power supplies (24 V DC) from Siemens, Schneider Electric and ABB, with over 200 products for control panels, PLCs and field devices. -
35 parts
DC UPS & Buffer Modules
DC UPS and buffer modules from Siemens, with over 30 SITOP products that keep 24 V DC controls running when the mains fails. -
51 parts
Redundancy, Selectivity & DC Converter Modules
Redundancy, selectivity and DC converter modules from Siemens, with over 50 products that protect 24 V DC supply systems and drive DC motors.
1SVR427035R0000 CP-E 24/10.0 ABB
ABB · CP-E 24/10.0 24VDC 10A 240W 115/230VAC Input DC Power Supply ABB1SVR427044R0200 CP-D 24/2.5 ABB
ABB · CP-D 24/2.5 24VDC 2.5A 60W 100-240VAC Input Switch Mode Power Supply ABB1SCA122946R1001 ODPS230 ABB
ABB · ABB 1SCA122946R1001 ODPS230 dual power supply, 220-240V, DIN-rail/screw mount, for transfer switches, EAN 6417019548807. ABB1SDA074172R1 EKIP SUPPLY 110-240VAC/DC E1.2..E6.2-XT ABB
ABB · EKIP SUPPLY 110-240VAC/DC E1.2..E6.2-XT Power Supply Module ABBCan't find the part you need?
Send the part numbers or the specs you need. We reply with price, stock and dispatch time per line.
Power Supplies buying guide
What's in this range
- DIN Rail Power Supplies (24V DC) – single-phase and 3-phase units for control panels.
- DC UPS & Buffer Modules – keep 24 V DC loads running through short mains outages.
- Redundancy, Selectivity & DC Converter Modules – redundant supply, channel protection and SINAMICS DCM DC converters.
How to choose
- Output current: add up all 24 V loads and keep about 20 to 30 percent reserve for inrush and future additions.
- Input: single-phase 100-240 V AC, 3-phase 400-500 V AC or a wide-range input depending on the site network.
- Application type: standard control supply, DC UPS for ride-through, or redundancy module for two supplies in parallel.
- Mounting and environment: DIN rail width, operating temperature and derating, and protection class.
Power Supplies questions
How do I size a 24 V DC power supply?
Total the current of all connected loads, then add a reserve. Choose the next standard rating above that figure, for example 10 A or 20 A.
What is the difference between a DC UPS and a buffer module?
A DC UPS module uses a battery to carry the load, often for minutes. A buffer module uses capacitors to bridge outages of a few hundred milliseconds.
Can you supply Siemens SITOP units internationally?
Yes. Stoklink ships worldwide from Turkey under EXW terms. Lead time depends on distributor stock, and bulk quotes are available on request.