Power Factor Correction
116 parts
Power factor correction (PFC) from Schneider Electric and ABB, with over 110 products to reduce reactive power in low-voltage networks. The range is mostly capacitors, such as VarPlus Can HDuty and EasyLogic, for network voltages from 400 V to 690 V. Stoklink ships worldwide from Turkey and quotes bulk orders on request.
BLRCS025A030B40 EasyLogicSchneider Electric · EasyLogic PFC capacitor, 2.5 kvar at 400 V, 50/60 Hz. IP20, double faston terminal.
BLRCS017A020B40 EasyLogicSchneider Electric · EasyLogic PFC capacitor, 1.7 kvar at 400 V, 50/60 Hz. IP20, double faston terminal.
BLRCS150A180B44 EasyLogicSchneider Electric · EasyLogic PFC capacitor, 15 kvar at 440 V, 50/60 Hz. IP20, clamptite terminal.
BLRCS010A012B40 EasyLogicSchneider Electric · EasyLogic PFC capacitor, 1 kvar at 400 V, 50/60 Hz. IP20, double faston terminal.
BLRCS150A180B40 EasyLogicSchneider Electric · EasyLogic PFC capacitor, 15 kvar at 400 V, 50/60 Hz. IP20, clamptite terminal.
BLRCH571A000B44 VarPlus Can HDutySchneider Electric · PowerLogic · VarPlus Can HDuty PFC capacitor, 57.1 kvar at 440 V, 50/60 Hz. IP00, stud terminals.
BLRCS143A172B44 EasyLogicSchneider Electric · EasyLogic PFC capacitor, 14.3 kvar at 440 V, 50/60 Hz. IP20, clamptite terminal.
BLRCH500A000B44 VarPlus Can HDutySchneider Electric · PowerLogic · VarPlus Can HDuty PFC capacitor, 50 kvar at 440 V, 50/60 Hz. IP00, stud terminals.
BLRCS125A150B52 EasyLogicSchneider Electric · EasyLogic PFC capacitor, 12.5 kvar at 525 V, 50/60 Hz. IP20, clamptite terminal.
BLRCH500A000B40 VarPlus Can HDutySchneider Electric · PowerLogic · VarPlus Can HDuty PFC capacitor, 50 kvar at 400 V, 50/60 Hz. IP00, stud terminals.
BLRCS125A150B48 EasyLogicSchneider Electric · EasyLogic PFC capacitor, 12.5 kvar at 480 V, 50/60 Hz. IP20, clamptite terminal.
BLRCH417A500B40 VarPlus Can HDutySchneider Electric · PowerLogic · VarPlus Can HDuty PFC capacitor, 41.7 kvar at 400 V, 50/60 Hz. IP00, clamptite terminal.
BLRCS125A150B44 EasyLogicSchneider Electric · EasyLogic PFC capacitor, 12.5 kvar at 440 V, 50/60 Hz. IP20, clamptite terminal.
BLRCH400A480B52 VarPlus Can HDutySchneider Electric · PowerLogic · VarPlus Can HDuty PFC capacitor, 40 kvar at 525 V, 50/60 Hz. IP00, stud terminals.
BLRCS125A150B40 EasyLogicSchneider Electric · EasyLogic PFC capacitor, 12.5 kvar at 400 V, 50/60 Hz. IP20, clamptite terminal.
1SFL431024R8000 UA95-30-00RA-80ABB · UA95-30-00RA-80 3P 145A 1000V 220-230V 50Hz Capacitor Contactor
1SBL411024R8000 UA75-30-00RA 220-230V 50Hz / 230-240V 60HzABB · UA..RA · UA75-30-00RA 220-230V 50Hz/230-240V 60Hz 3-Pole Capacitor Contactor
1SFL451024R8000 UA110-30-00RA-80ABB · UA110-30-00RA-80 3P 160A 1000V 220-230V 50Hz Capacitor Contactor
1SBL241024R8010 UA26-30-10RA 220-230V 50Hz / 230-240V 60HzABB · UA26-30-10RA 220-230V 50Hz/230-240V 60Hz 3-Pole Capacitor Contactor
Can't find the part you need?
Send the part numbers or the specs you need. We reply with price, stock and dispatch time per line.
Power Factor Correction buying guide
What's in this range
- Schneider Electric VarPlus Can HDuty capacitors, for example 15 kvar at 400 V and 31.5 kvar at 480 V.
- Schneider Electric EasyLogic capacitors for standard duty, including 440 V and 525 V versions.
- Capacitors rated 50 Hz for 400 V, 440 V, 480 V, 525 V and 690 V networks.
- A small ABB selection of related components.
How to choose
- Reactive power: calculate the kvar from active power, present power factor and target power factor.
- Rated voltage: select a capacitor voltage above the network voltage, since harmonics and voltage rise stress the dielectric.
- Duty class: standard duty suits clean networks, while heavy duty types handle higher harmonic and inrush current.
- Harmonics: with variable frequency drives on the network, check whether detuned reactors are needed.
Power Factor Correction questions
How do I calculate the kvar I need?
Multiply the active power in kW by the difference of the tangents of the present and target power factor angles.
What is the difference between standard and heavy duty capacitors?
Heavy duty types tolerate higher overload current and harmonic content. They are the safer choice on networks with drives or rectifiers.
Can you supply capacitors in project quantities?
Yes. Request a quote with the voltage and kvar list. Stoklink ships worldwide from Turkey under EXW terms.