Contactors
973 parts 4 sub-families 7 series
Contactors from ABB, Schneider Electric and Siemens switch motor and load circuits on and off by remote control. This range covers over 900 products, from 2 A accessories to power contactors rated up to 2650 A, with motor ratings from 2.2 kW to 450 kW in 2, 3, 4 and 8 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
4 sub-families of Contactors
-
665 parts
Power Contactors (AC-3)
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. AFTeSys Deca3RT2 -
77 parts
Contactor Relays & Auxiliary Contactors
Contactor relays and auxiliary contactors from ABB and Schneider Electric switch control circuits in panels. -
14 parts
Installation Contactors
Installation contactors from ABB switch lighting, heating and other building loads from a distribution board. -
204 parts
Contactor Accessories (Coils, Aux Blocks)
Contactor accessories from ABB and Schneider Electric extend or repair contactors with coils, auxiliary contact blocks and mounting parts.
LC1DFKF7 LC1DFK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 12.5 kvar at 400 V, 110 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DMKF7 LC1DMK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 25 kvar at 400 V, 110 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DMKM7 LC1DMK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 25 kvar at 400 V, 220 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DFKM7 LC1DFK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 12.5 kvar at 400 V, 220 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DMKV7 LC1DMK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 25 kvar at 400 V, 400 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DFKV7 LC1DFK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 12.5 kvar at 400 V, 400 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DPKM7 LC1DPK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 30 kvar at 400 V, 220 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DGKF7 LC1DGK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 16.7 kvar at 400 V, 110 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DGKM7 LC1DGK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 16.7 kvar at 400 V, 220 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DTKM7 LC1DTK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 40 kvar at 400 V, 220 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DWK12F7 LC1DWK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 63 kvar at 400 V, 110 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DLKM7 LC1DLK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 20 kvar at 400 V, 220 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DWK12M7 LC1DWK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 63 kvar at 400 V, 220 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DT40F7 LC1D Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca 4P contactor, 40 A AC-1 resistive load at ≤440 V AC, 110 V AC 50/60 Hz coil, 1NO+1NC mirror contacts. Schneider ElectricLC1DWK12Q7 LC1DWK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 63 kvar at 400 V, 380 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DT60AB7 LC1D Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca 4P contactor, 60 A AC-1 resistive load at ≤440 V AC, 24 V AC 50/60 Hz coil, 1NO+1NC mirror contacts. Schneider ElectricLC1DWK12V7 LC1DWK Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca capacitor-duty contactor, 63 kvar at 400 V, 400 V AC 50/60 Hz coil, 1NO+2NC contacts. Schneider ElectricLC1DT80AF7 LC1D Schneider Electric
Schneider Electric · Schneider Electric TeSys Deca 4P contactor, 80 A AC-1 resistive load at ≤440 V AC, 110 V AC 50/60 Hz coil, 1NO+1NC mirror contacts. Schneider ElectricLC1K0601Q7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 6 A AC-3 (2.2 kW at 400 V), 1NC aux, 380-400 V AC 50/60 Hz coil. Schneider ElectricLC1G1504EHEN LC1G Schneider Electric
Schneider Electric · Schneider Electric TeSys Giga 4P contactor, 275 A AC-1 at ≤440 V, 48-130 V AC/DC coil, plate mount, Contact Wear Diagnosis. Schneider ElectricLC1K0901F7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 9 A AC-3 (4 kW at 400 V), 1NC aux, 110 V AC 50/60 Hz coil. Schneider ElectricLC1G150EHEN LC1G Schneider Electric
Schneider Electric · Schneider Electric TeSys Giga 3P contactor, 150 A AC-3 (75 kW at 400 V), 48-130 V AC/DC coil, plate mount. Schneider ElectricLC1K0901Q7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 9 A AC-3 (4 kW at 400 V), 1NC aux, 380-400 V AC 50/60 Hz coil. Schneider ElectricLC1G1854LSEA LC1G Schneider Electric
Schneider Electric · Schneider Electric TeSys Giga 4P contactor, 305 A AC-1 at ≤440 V, 200-500 V AC/DC coil, plate mount, Contact Wear Diagnosis. Schneider ElectricLC1K1201E7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 12 A AC-3 (5.5 kW at 400 V), 1NC aux, 48 V AC 50/60 Hz coil. Schneider ElectricLC1G185EHEN LC1G Schneider Electric
Schneider Electric · Schneider Electric TeSys Giga 3P contactor, 185 A AC-3 (90 kW at 400 V), 48-130 V AC/DC coil, plate mount. Schneider ElectricLC1K1210Q7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 12 A AC-3 (5.5 kW at 400 V), 1NO aux, 380-400 V AC 50/60 Hz coil. Schneider ElectricLC1G2254LSEA LC1G Schneider Electric
Schneider Electric · Schneider Electric TeSys Giga 4P contactor, 330 A AC-1 at ≤440 V, 200-500 V AC/DC coil, plate mount, Contact Wear Diagnosis. Schneider ElectricLC1K1610F7 LC1K Schneider Electric
Schneider Electric · Schneider Electric TeSys K 3P mini contactor, 16 A AC-3 (7.5 kW at 400 V), 1NO aux, 110 V AC 50/60 Hz coil. Schneider ElectricLC1G2654LSEA LC1G Schneider Electric
Schneider Electric · Schneider Electric TeSys Giga 4P contactor, 385 A AC-1 at ≤440 V, 200-500 V AC/DC coil, plate mount, Contact Wear Diagnosis. Schneider ElectricLADN22R LADN_R Schneider Electric
Schneider Electric · 2NO+2NC auxiliary contact block, 690 V AC, 10 A Ith, screw clamp terminals, for TeSys Deca LC1D/LC1F/CAD. Schneider ElectricLAEN02 LAEN Schneider Electric
Schneider Electric · 2NC mirror-contact auxiliary block, 690 V AC, 8 A Ith, screw clamp terminals, for EasyPact TVS LC1E contactors. Schneider ElectricLC1G3304EHEN LC1G Schneider Electric
Schneider Electric · Schneider Electric TeSys Giga 4P contactor, 440 A AC-1 at ≤440 V, 48-130 V AC/DC coil, plate mount, Contact Wear Diagnosis. Schneider ElectricLADN40R LADN_R Schneider Electric
Schneider Electric · 4NO auxiliary contact block, 690 V AC, 10 A Ith, screw clamp terminals, for TeSys Deca LC1D/LC1F/CAD. Schneider ElectricLAEN11 LAEN Schneider Electric
Schneider Electric · 1NO+1NC mirror-contact auxiliary block, 690 V AC, 8 A Ith, screw clamp terminals, for EasyPact TVS LC1E contactors. Schneider ElectricLC1G330EHEN LC1G Schneider Electric
Schneider Electric · Schneider Electric TeSys Giga 3P contactor, 330 A AC-3 (160 kW at 400 V), 48-130 V AC/DC coil, plate mount. Schneider ElectricLAEN20 LAEN Schneider Electric
Schneider Electric · 2NO auxiliary contact block, 690 V AC, 8 A Ith, screw clamp terminals, for EasyPact TVS LC1E contactors. Schneider ElectricLAEB1 LAEB Schneider Electric
Schneider Electric · Removable terminal block for separate DIN-rail or screw mounting of LRE01-E35 EasyPact TVS overload relays. Schneider ElectricLC1G4004EHEN LC1G Schneider Electric
Schneider Electric · Schneider Electric TeSys Giga 4P contactor, 550 A AC-1 at ≤440 V, 48-130 V AC/DC coil, plate mount, Contact Wear Diagnosis. Schneider ElectricLC1G5004LSEA LC1G Schneider Electric
Schneider Electric · Schneider Electric TeSys Giga 4P contactor, 700 A AC-1 at ≤440 V, 200-500 V AC/DC coil, plate mount, Contact Wear Diagnosis. Schneider ElectricLAEN22 LAEN Schneider Electric
Schneider Electric · 2NO+2NC auxiliary contact block, 690 V AC, 8 A Ith, screw clamp terminals, for EasyPact TVS LC1E contactors. Schneider ElectricLAEB3 LAEB Schneider Electric
Schneider Electric · Removable terminal block for separate DIN-rail or screw mounting of LRE322-E365 EasyPact TVS overload relays. Schneider ElectricLAEM1 LAEM Schneider Electric
Schneider Electric · Mechanical interlock kit for pairing LC1E06-E65 EasyPact TVS contactors in reversing or changeover assemblies. Schneider ElectricLAEM4 LAEM Schneider Electric
Schneider Electric · Mechanical interlock kit for pairing LC1E80-E95 EasyPact TVS contactors in reversing or changeover assemblies. Schneider ElectricLC1D12ED LC1D Schneider Electric
Schneider Electric · TeSys Deca 3P contactor, 12A AC-3, 5.5kW at 400V, 48 V DC coil. Schneider ElectricLC1D38ED LC1D Schneider Electric
Schneider Electric · TeSys Deca 3P contactor, 38A AC-3, 18.5kW at 400V, 48 V DC coil. Schneider ElectricLC1D38F7 LC1D Schneider Electric
Schneider Electric · TeSys Deca 3P contactor, 38A AC-3, 18.5kW at 400V, 110 V AC coil. Schneider ElectricCan't find the part you need?
Send the part numbers or the specs you need. We reply with price, stock and dispatch time per line.
Contactors buying guide
What's in this range
- Power Contactors (AC-3) – the main motor-switching contactors, including ABB AF, TeSys Deca, TeSys Giga, TeSys K, Easy TeSys and SIRIUS 3RT2 and 3RT1.
- Contactor Relays & Auxiliary Contactors – control-circuit relays with several auxiliary contacts.
- Installation Contactors – DIN-rail contactors for distribution boards, such as ABB ESB.
- Contactor Accessories (Coils, Aux Blocks) – replacement coils, auxiliary contact blocks and mounting parts.
How to choose
- Utilization category: AC-3 for squirrel-cage motor starting, AC-1 for resistive loads. The same frame carries a different current in each category.
- Rated current and motor power at your operating voltage, with margin for the duty cycle.
- Number of poles: 3P for three-phase motors, 4P for switching the neutral or four-wire loads.
- Coil voltage and type (AC, DC or AC/DC). It must match the control supply.
- Auxiliary contacts: count the NO and NC contacts the control circuit needs, and check if the contactor accepts add-on blocks.
Contactors questions
What is the difference between a contactor and a contactor relay?
A power contactor switches the main circuit of a motor or load. A contactor relay switches control circuits at low current, typically 10 A, and has more auxiliary contacts.
Which standard applies to contactors?
Low-voltage contactors are covered by IEC 60947-4-1. The standard defines utilization categories such as AC-1 and AC-3.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.