Contactors
973 parts 4 sub-families 7 series
Contactors from ABB, Schneider Electric and Siemens switch motor and load circuits on and off by remote control. This range covers over 900 products, from 2 A accessories to power contactors rated up to 2650 A, with motor ratings from 2.2 kW to 450 kW in 2, 3, 4 and 8 pole versions. Stoklink ships worldwide from Turkey and quotes project volumes on request.
4 sub-families of Contactors
-
665 parts
Power Contactors (AC-3)
Power contactors (AC-3) from ABB, Schneider Electric and Siemens start and stop three-phase motors and switch heavy loads. AFTeSys Deca3RT2 -
77 parts
Contactor Relays & Auxiliary Contactors
Contactor relays and auxiliary contactors from ABB and Schneider Electric switch control circuits in panels. -
14 parts
Installation Contactors
Installation contactors from ABB switch lighting, heating and other building loads from a distribution board. -
204 parts
Contactor Accessories (Coils, Aux Blocks)
Contactor accessories from ABB and Schneider Electric extend or repair contactors with coils, auxiliary contact blocks and mounting parts.
LC1D32D7 LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D32D7 TeSys Deca contactor, 3P 3NO, AC-3 32 A, 42 V AC coil. Schneider ElectricLC1D32BNE LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D32BNE TeSys Deca contactor, 3P 3NO, AC-3 32 A, 24-60 V AC/DC coil. Schneider ElectricLC1D32BL LC1D Schneider Electric
Schneider Electric · TeSys Deca LC1D contactor, 3P 3NO, 32 A AC-3 (15 kW at 400 V), 24 V DC low-consumption coil, 1 NO+1 NC mirror-certified auxiliary contact. Schneider ElectricLC1D25V7 LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D25V7 TeSys Deca contactor, 3P 3NO, AC-3 25 A, 400 V AC coil. Schneider ElectricLC1D25KUE LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D25KUE TeSys Deca contactor, 3P 3NO, AC-3 25 A, 100-250 V AC/DC coil. Schneider ElectricLC1D25FD LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D25FD TeSys Deca contactor, 3P 3NO, AC-3 25 A, 110 V DC coil. Schneider ElectricLC1D25ED LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D25ED TeSys Deca contactor, 3P 3NO, AC-3 25 A, 48 V DC coil. Schneider ElectricLC1D25BNE LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D25BNE TeSys Deca contactor, 3P 3NO, AC-3 25 A, 24-60 V AC/DC coil. Schneider ElectricLC1D25BL LC1D Schneider Electric
Schneider Electric · TeSys Deca LC1D contactor, 3P 3NO, 25 A AC-3 (11 kW at 400 V), low-consumption 24 V DC coil, 1 NO + 1 NC auxiliary. Schneider ElectricLC1D18V7 LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D18V7 TeSys Deca contactor, 3P 3NO, AC-3 18 A, 400 V AC coil. Schneider ElectricLC1D18Q7 LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D18Q7 TeSys Deca contactor, 3P 3NO, AC-3 18 A, 380 V AC coil. Schneider ElectricLC1D18KUE LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D18KUE TeSys Deca contactor, 3P 3NO, AC-3 18 A, 100-250 V AC/DC coil. Schneider ElectricLC1D18FD LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D18FD TeSys Deca contactor, 3P 3NO, AC-3 18 A, 110 V DC coil. Schneider ElectricLC1D18ED LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D18ED TeSys Deca contactor, 3P 3NO, AC-3 18 A, 48 V DC coil. Schneider ElectricLC1D18D7 LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D18D7 TeSys Deca contactor, 3P 3NO, AC-3 18 A, 42 V AC coil. Schneider ElectricLC1D12Q7 LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D12Q7 TeSys Deca contactor, 3P 3NO, AC-3 12 A, 380 V AC coil. Schneider ElectricLC1D12FD LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D12FD TeSys Deca contactor, 3P 3NO, AC-3 12 A, 110 V DC coil. Schneider ElectricLC1D12D7 LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D12D7 TeSys Deca contactor, 3P 3NO, AC-3 12 A, 42 V AC coil. Schneider ElectricLC1D12BL LC1D Schneider Electric
Schneider Electric · TeSys Deca LC1D contactor, 3P 3NO, 12 A AC-3 (5.5 kW at 400 V), low-consumption 24 V DC coil, 1 NO + 1 NC auxiliary. Schneider ElectricLC1D09V7 LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D09V7 TeSys Deca contactor, 3P 3NO, AC-3 9 A, 400 V AC coil. Schneider ElectricLC1D09KUE LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D09KUE TeSys Deca contactor, 3P 3NO, AC-3 9 A, 100-250 V AC/DC coil. Schneider ElectricLC1D09FD LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D09FD TeSys Deca contactor, 3P 3NO, AC-3 9 A, 110 V DC coil. Schneider ElectricLC1D09ED LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D09ED TeSys Deca contactor, 3P 3NO, AC-3 9 A, 48 V DC coil. Schneider ElectricLC1D09D7 LC1D Schneider Electric
Schneider Electric · Schneider Electric LC1D09D7 TeSys Deca contactor, 3P 3NO, AC-3 9 A, 42 V AC coil. Schneider ElectricLADN31R TeSys Deca Auxiliary Contact Block (LADN_R) Schneider Electric
Schneider Electric · TeSys Deca auxiliary contact block, 3NO+1NC, front mount, 10 A, 690 V AC, dust-resistant 3S4. Schneider ElectricLADN20R TeSys Deca Auxiliary Contact Block (LADN_R) Schneider Electric
Schneider Electric · TeSys Deca auxiliary contact block, 2NO, front mount, 10 A, 690 V AC, dust-resistant 3S4. Schneider ElectricLADN11R TeSys Deca Auxiliary Contact Block (LADN_R) Schneider Electric
Schneider Electric · TeSys Deca auxiliary contact block, 1NO+1NC, front mount, 10 A, 690 V AC, dust-resistant 3S4. Schneider ElectricLADC22 TeSys Deca Auxiliary Contact Block Schneider Electric
Schneider Electric · TeSys Deca auxiliary contact block, 2NO+2NC (1NO+1NC make-before-break), front mount, 10 A, 690 V AC. Schneider ElectricLAD8N02 TeSys Deca Auxiliary Contact Block Schneider Electric
Schneider Electric · TeSys Deca auxiliary contact block, 2NC, side mount, 10 A Ith, 690 V AC, screw clamp terminals. Schneider ElectricLC1E95B5 LC1E Schneider Electric
Schneider Electric · Schneider Electric LC1E95B5 Easy TeSys contactor, 3P 3NO, AC-3 95 A, 24 V AC coil. Schneider ElectricLC1E95004M7 LC1E Schneider Electric
Schneider Electric · Schneider Electric LC1E95004M7 Easy TeSys contactor, 4P 4NO, AC-1 125 A, 220 V AC coil. Schneider ElectricLC1E80004M7 LC1E Schneider Electric
Schneider Electric · Schneider Electric LC1E80004M7 Easy TeSys contactor, 4P 4NO, AC-1 100 A, 220 V AC coil. Schneider ElectricLC1E65004M7 LC1E Schneider Electric
Schneider Electric · Schneider Electric LC1E65004M7 Easy TeSys contactor, 4P 4NO, AC-1 80 A, 220 V AC coil. Schneider ElectricLC1E630M7 LC1E Schneider Electric
Schneider Electric · Easy TeSys Control 3P power contactor, 630A AC-3 at 440V, 220V AC coil, 335kW motor rating, bar terminals. Schneider ElectricLC1E50B5 LC1E Schneider Electric
Schneider Electric · Schneider Electric LC1E50B5 Easy TeSys contactor, 3P 3NO, AC-3 50 A, 24 V AC coil. Schneider ElectricLC1E500M7 LC1E Schneider Electric
Schneider Electric · Easy TeSys Control 3P power contactor, 500A AC-3 at 440V, 220V AC coil, 250kW motor rating, bar terminals. Schneider ElectricLC1E40004M7 LC1E Schneider Electric
Schneider Electric · Schneider Electric LC1E40004M7 Easy TeSys contactor, 4P 4NO, AC-1 60 A, 220 V AC coil. Schneider ElectricLC1E3801BD LC1E Schneider Electric
Schneider Electric · Easy TeSys Control 3P contactor, 38A AC-3 at 440V, 24V DC coil, 1 NC auxiliary contact, 18.5kW motor rating. Schneider ElectricLC1E38004M7 LC1E Easy TeSys Contactor Schneider Electric
Schneider Electric · Easy TeSys contactor, 4P, 50 A AC-1 resistive load, 220 V AC coil, DIN rail mount. Schneider ElectricLC1E3210BD LC1E Schneider Electric
Schneider Electric · Easy TeSys Control 3P contactor, 32A AC-3 at 440V, 24V DC coil, 1 NO auxiliary contact, 15kW motor rating. Schneider ElectricLC1E3210B5 LC1E Easy TeSys Contactor Schneider Electric
Schneider Electric · Easy TeSys contactor, 3P, 32 A AC-3, 15 kW at 415/440 V, 24 V AC coil, 1NO auxiliary contact. Schneider ElectricLC1E250B5 LC1E Easy TeSys Contactor Schneider Electric
Schneider Electric · Easy TeSys contactor, 3P, 250 A AC-3, 140 kW at 415/440 V, 24 V AC coil, no built-in auxiliary contacts. Schneider ElectricLC1E2501B5 LC1E Easy TeSys Contactor Schneider Electric
Schneider Electric · Easy TeSys contactor, 3P, 25 A AC-3, 11 kW at 415/440 V, 24 V AC coil, 1NC auxiliary contact. Schneider ElectricLC1E25004M7 LC1E Easy TeSys Contactor Schneider Electric
Schneider Electric · Easy TeSys contactor, 4P, 40 A AC-1 resistive load, 220 V AC coil, DIN rail mount. Schneider ElectricLC1E200B5 LC1E Easy TeSys Contactor Schneider Electric
Schneider Electric · Easy TeSys contactor, 3P, 200 A AC-3, 100 kW at 415/440 V, 24 V AC coil, no built-in auxiliary contacts. Schneider ElectricLC1E18004M7 LC1E Easy TeSys Contactor Schneider Electric
Schneider Electric · Easy TeSys contactor, 4P, 32 A AC-1 resistive load, 220 V AC coil, no built-in auxiliary contacts. Schneider ElectricLC1E160B5 LC1E Easy TeSys Contactor Schneider Electric
Schneider Electric · Easy TeSys contactor, 3P, 160 A AC-3, 80 kW at 415/440 V, 24 V AC coil, 1NO+1NC auxiliary contacts. Schneider ElectricCan't find the part you need?
Send the part numbers or the specs you need. We reply with price, stock and dispatch time per line.
Contactors buying guide
What's in this range
- Power Contactors (AC-3) – the main motor-switching contactors, including ABB AF, TeSys Deca, TeSys Giga, TeSys K, Easy TeSys and SIRIUS 3RT2 and 3RT1.
- Contactor Relays & Auxiliary Contactors – control-circuit relays with several auxiliary contacts.
- Installation Contactors – DIN-rail contactors for distribution boards, such as ABB ESB.
- Contactor Accessories (Coils, Aux Blocks) – replacement coils, auxiliary contact blocks and mounting parts.
How to choose
- Utilization category: AC-3 for squirrel-cage motor starting, AC-1 for resistive loads. The same frame carries a different current in each category.
- Rated current and motor power at your operating voltage, with margin for the duty cycle.
- Number of poles: 3P for three-phase motors, 4P for switching the neutral or four-wire loads.
- Coil voltage and type (AC, DC or AC/DC). It must match the control supply.
- Auxiliary contacts: count the NO and NC contacts the control circuit needs, and check if the contactor accepts add-on blocks.
Contactors questions
What is the difference between a contactor and a contactor relay?
A power contactor switches the main circuit of a motor or load. A contactor relay switches control circuits at low current, typically 10 A, and has more auxiliary contacts.
Which standard applies to contactors?
Low-voltage contactors are covered by IEC 60947-4-1. The standard defines utilization categories such as AC-1 and AC-3.
Do you ship contactors outside Turkey?
Yes. Stoklink ships worldwide from Turkey on EXW terms. Lead time depends on distributor stock, so send the part numbers for a quote. Project quantities are quoted on request.