- Home
- All Products
- Siemens 6XV1875-5LH10 SCALANCE M N-Connect/SMA m/m 1m Antenna Cable Siemens 6XV1875-5LH10 SCALANCE M N-Connect/SMA m/m 1m Antenna Cable
Siemens 6XV1875-5LH10 SCALANCE M N-Connect/SMA m/m 1m Antenna Cable
Get Quote
- Description
The Siemens 6XV1875-5LH10 is a preassembled SCALANCE M antenna connection cable with N-Connect and SMA male connectors, supplied in a 1 m length for a 0-6000 MHz transmission range at 50 Ω impedance. Attenuation runs 0.53 dB/m at 2.4 GHz, rising to 0.89 dB/m at 5.85 GHz. It is rated for -40 to +80 °C operation with a halogen-free FRNC sheath rated to 80 N tensile load.
Technical Specifications
| Order Number (MLFB) | 6XV1875-5LH10 |
| EAN | 4019169855389 |
| Brand | Siemens |
| Series | SCALANCE M |
| Product Type Designation | Antenna connection cable, N-Connect/SMA plug/plug |
| Suitability | Connecting an antenna to SCALANCE M |
| Cable Length | 1 m |
| Number of Electrical Connections | 2 |
| Type of Electrical Connection | N-Connect/SMA male/male |
| Transmission Frequency | 0 - 6000 MHz |
| Attenuation at 2.4 GHz (typical) | 0.53 dB/m |
| Attenuation at 5.2 GHz (typical) | 0.83 dB/m |
| Attenuation at 5.85 GHz (typical) | 0.89 dB/m |
| Return Loss (minimum) | 23 dB |
| Impedance | 50 Ω |
| Capacitance per Length (at 1 kHz) | 82 pF/m |
| Relative Propagation Speed | 82 percent |
| Shield Design | Braided shield, tin-plated copper wires |
| Inner Conductor Diameter | 1.4 mm |
| Dielectric Diameter | 3.8 mm |
| Cable Sheath Diameter | 6.3 mm |
| Sheath Diameter Tolerance | 0.2 mm |
| Cable Sheath Thickness | 1.76 mm |
| Inner Conductor Material | Cu |
| Dielectric Material | Polyethylene foam |
| Cable Sheath Material | FRNC |
| Cable Sheath Color | Pastel turquoise |
| Bending Radius, Single Bend (min) | 32 mm |
| Bending Radius, Multiple Bends (min) | 45 mm |
| Maximum Tensile Load | 80 N |
| Weight per Length | 75 kg/km |
| Net Weight | 0.119 kg |
| Operating Temperature | -40 to +80 °C |
| Storage Temperature | -40 to +80 °C |
| Transport Temperature | -40 to +80 °C |
| Installation Temperature | -25 to +80 °C |
| Chemical Resistance to Mineral Oil | Conditional resistance |
| UV Resistance | Resistant |
| Protection Class IP | When plugged in |
| Halogen-Free | Yes |
| Silicone-Free | Yes |
| Fire Behavior Standard | UL 1685 Vertical Tray, UL 1581 Sec. 1090 H |
| Country of Origin | Germany |
Certifications & Standards
- EAC
- RoHS
Selection Notes
Choose the 1 m length when the antenna mounts close to the SCALANCE M enclosure, for example inside the same cabinet or on an adjacent panel — at 1 m, cumulative attenuation stays at roughly 0.53 dB at 2.4 GHz and 0.89 dB at 5.85 GHz, the lowest loss in this cable family. The 2 m and 5 m variants use the identical N-Connect/SMA male/male termination and electrical specification, so the only trade-off when moving to a longer run is proportionally higher insertion loss against greater routing reach.