- Home
- All Products
- Siemens 6XV1870-3QN30 SIMATIC NET IE TP Cord RJ45/RJ45 Cat6a 30m Industrial Network Cable Siemens 6XV1870-3QN30 SIMATIC NET IE TP Cord RJ45/RJ45 Cat6a 30m Industrial Network Cable
Siemens 6XV1870-3QN30 SIMATIC NET IE TP Cord RJ45/RJ45 Cat6a 30m Industrial Network Cable
Get Quote
- Description
The Siemens 6XV1870-3QN30 is a pre-assembled Industrial Ethernet TP cord with two latched RJ45 connectors, built to Cat6A S/FTP shielding on a 30 m fixed length. It supports 10/100/1000/10000 Mbit/s links plus PoE, PoE+ and PoE++ power delivery, sized for longer cabinet-to-field or building-span runs made with a single continuous cable run.
Technical Specifications
| SKU / Order Number | 6XV1870-3QN30 |
| Brand | Siemens |
| Series | SIMATIC NET |
| EAN | 4019169855280 |
| Product Type Designation | IE TP Cord RJ45/RJ45, 4x2 |
| Description | Patch cable, preassembled with two RJ45 connectors (10/100/1000/10000 MB) |
| Cable Designation | S/FTP, LI 02YSCH 4x2x0.15 PIMF GN FRNC |
| Wire Length | 30 m |
| Connector Type | RJ45, latched |
| Number of Electrical Connections | 2 |
| Number of Electrical Cores | 8 |
| Cabling Standard | Cat6A (ISO/IEC 11801-1, IEC 61035) |
| Shield Design | S/FTP - overlapped aluminum-clad foil, braided tinned copper shield |
| Attenuation @ 10 / 100 MHz (Max.) | 0.086 dB/m / 0.28 dB/m |
| Attenuation @ 300 / 600 MHz (Max.) | 0.501 dB/m / 0.735 dB/m |
| Impedance | 100 ohm |
| Coupling Loss @ 30-100 MHz (Min.) | 70 dB |
| Transfer Impedance per Length @ 10 MHz | 10 mOhm/m |
| Loop Resistance per Length (Max.) | 290 mOhm/m |
| Operating Voltage (RMS) | 80 V |
| NVP Value | 80 % |
| Outer Diameter, Cable Sheath | 6.2 mm |
| Weight per Length | 50 kg/km |
| Bending Radius, Single Bend (Min.) | 31 mm |
| Bending Radius, Multiple Bend (Min.) | 43.5 mm |
| Operating / Storage / Transport Temperature | -25 to +80 C |
| Installation Temperature | -25 to +80 C |
| Fire Behavior | Flame-resistant acc. to IEC 60332-1-2, EN 60332-3-24 |
| Burning Behaviour Class (EN 13501-6) | Eca |
| Oil Resistance | Oil-resistant acc. to IEC 60811-2-1 (4h/70C) |
| UV Resistance | Not resistant |
| Protection Class | IP20 |
| Halogen-Free | Yes, acc. to EN 60754-2 |
| PoE / PoE+ / PoE++ Capability | Yes / Yes / Yes |
| Test Voltage, Core-to-Core / Core-Shield | 500 V / 1500 V |
| Net Weight | 0.498 kg |
Certifications & Standards
- EAC
- UL
- RoHS
Selection Notes
At 30 m this cord covers longer building-span runs, approaching the practical limit where Cat6A permanent-link attenuation budgets start to matter for 10GBASE-T; for full 10 Gbit/s performance over this length, verify the end-to-end channel against ISO/IEC 11801-1 rather than assuming headroom. Shield, connector type and PoE++ rating match the rest of the family; the 35 m cord is the next step up, the 20 m or shorter cords the step down.