- Home
- All Products
- Siemens 6ES7158-3AD10-0XA0 SIMATIC PN/PN Coupler 2-Port IRT Remote I/O Interface Module Siemens 6ES7158-3AD10-0XA0 SIMATIC PN/PN Coupler 2-Port IRT Remote I/O Interface Module
Siemens 6ES7158-3AD10-0XA0 SIMATIC PN/PN Coupler 2-Port IRT Remote I/O Interface Module
Get Quote
- Description
The Siemens 6ES7158-3AD10-0XA0 SIMATIC PN/PN Coupler is a remote I/O interface module that connects up to four PROFINET IO controllers per subnet, including subnet-to-subnet coupling, over two PROFINET ports fitted via SIMATIC BusAdapter. It supports IRT with Dynamic Frame Packing, PROFIsafe data exchange, and a 24 V DC supply rated 19.2-28.8 V with reverse-polarity protection.
Technical Specifications
| SKU | 6ES7158-3AD10-0XA0 |
| Brand | Siemens |
| Series | SIMATIC ET 200 |
| Product type designation | PN/PN coupler |
| Firmware version | V6.0 |
| Number of coupling modules | 16 (non-isochronous mode), 3 in isochronous mode |
| Record length, max. | 4096 byte |
| Address space per module, max. | 254 byte |
| Address space per station, max. | 1440 byte |
| Supply voltage, rated value (DC) | 24 V |
| Supply voltage, permissible range | 19.2-28.8 V DC |
| Current consumption, max. | 360 mA |
| Power loss, typ. | 4 W |
| Number of PROFINET interfaces | 2 (via BusAdapter) |
| Transmission rate, max. | 100 Mbit/s |
| IRT | Yes |
| Media redundancy | MRP / MRPD |
| Ambient temperature, operation | -30 to 60 degrees C (horizontal) |
| Dimensions (W x H x D) | 100 x 117 x 74 mm |
| Weight, approx. | 200 g (without BusAdapter) |
Selection Notes
The 16 configurable coupling modules split 1 write / 3 read submodules each in non-isochronous mode, so plan the input/output record split before commissioning since that ratio is fixed. Switching to isochronous mode drops capacity to 3 coupling modules with 500 microsecond cycles, so choose non-isochronous operation when the full 16-module count is needed. The unit ships without a BusAdapter, so an RJ45, FC, or optical (LC/SCRJ) BusAdapter pair must be ordered separately to match the target port count and medium.
Applications
Use the 6ES7158-3AD10-0XA0 to exchange I/O, MSI/MSO, and data-record traffic between up to four PROFINET IO controllers on the same subnet or across two subnets without a shared master controller, such as linking a machine cell's local PLC to a plant-wide line controller while keeping each PROFINET domain separate. PROFIsafe pass-through carries safety data across that same boundary, and PROFINET system redundancy (S2) in non-isochronous mode keeps the coupling available if one controller connection drops.