- Home
- All Products
- Schneider Electric XB5S2B2L2 Harmony XB5S Biometric Switch Monostable 22 mm 2m Cable 24 V DC Control Unit Schneider Electric XB5S2B2L2 Harmony XB5S Biometric Switch Monostable 22 mm 2m Cable 24 V DC Control Unit
Schneider Electric XB5S2B2L2 Harmony XB5S Biometric Switch Monostable 22 mm 2m Cable 24 V DC Control Unit
Schneider Electric XB5S2B2L2 Harmony XB5S Biometric Switch Monostable 22 mm 2m Cable 24 V DC Control Unit
Get Quote
- Description
The Schneider Electric XB5S2B2L2 is a Harmony XB5S monostable fingerprint biometric switch in a 22 mm dark grey plastic bezel, supplied at 24 V DC with a pre-wired 2 m cable. It replaces a mechanical key switch with momentary fingerprint-based access control for machine commands or area authorization, storing up to 200 users.
Technical Specifications
| Reference | XB5S2B2L2 |
| Brand | Schneider Electric |
| Range of Product | Harmony XB5S |
| GTIN | 3606480061417 |
| Product or Component Type | Biometric switch |
| Device Short Name | XB5S |
| Bezel Material | Dark grey plastic |
| Mounting Diameter | 22 mm |
| Output Type | PNP |
| Operator Profile | Fingerprint reader, momentary |
| Function of Module | Monostable |
| Electrical Connection | Pre-wired cable, 3 x 0.34 mm^2, 2 m |
| Memory Usage | 200 users, up to 2 fingerprints each |
| [Us] Rated Supply Voltage | 24 V DC (limits 20...30 V DC) |
| Maximum Switching Current | 200 mA |
| Current Consumption | <= 70 mA, no load |
| Local Signalling | Green/orange/red status LEDs |
| IP Degree of Protection | IP20 rear, IP65 front |
| Ambient Air Temperature (Operation) | -5...50 degC |
| Net Weight | 0.17 kg |
Certifications & Standards
- CE
- UL
- CSA
- IEC 61000-6-4
- IEC 61000-6-2
Selection Notes
The monostable function outputs only while a valid fingerprint is held at the reader, which suits a momentary enable signal such as a hold-to-run or interlock release; the bistable XB5S2B2L2 sibling, XB5S1B2L2, latches the output instead for an access-enable circuit that should stay on. The pre-wired 2 m cable version suits a panel close enough for direct termination; the M12-connector XB5S2B2M12 variant suits a plug-in field connection instead. With 200 mA switching capacity on a 24 V DC output, it interfaces directly with a PLC digital input.