- Home
- All Products
- Schneider Electric LUCB12FU TeSys U Advanced Control Unit 3-12 A 110-240 V AC/DC Motor Starter Module Schneider Electric LUCB12FU TeSys U Advanced Control Unit 3-12 A 110-240 V AC/DC Motor Starter Module
Schneider Electric LUCB12FU TeSys U Advanced Control Unit 3-12 A 110-240 V AC/DC Motor Starter Module
Schneider Electric LUCB12FU TeSys U Advanced Control Unit 3-12 A 110-240 V AC/DC Motor Starter Module
Get Quote
- Description
The Schneider Electric LUCB12FU is a TeSys U advanced control unit with an adjustable motor current range of 3-12 A, inserted into a compatible power base to form a starter controller for 3-phase motors up to 5.5 kW at 400-440 V AC. It provides Class 10 thermal overload protection, phase-failure sensing, and a 110-240 V AC/DC control coil, plus a thermal overload alarm usable locally via a LUFDA module or remotely via a LULC module, and a test push button for overload simulation.
Technical Specifications
| Reference | LUCB12FU |
| Brand | Schneider Electric |
| Range | TeSys |
| Product Name | TeSys Ultra |
| GTIN | 3389110364439 |
| Product or Component Type | Advanced control unit |
| Device Application | Motor control, motor protection |
| Product Compatibility | Power base LUB12, LUB32, LUB38, LUB120, LUB320, LUB380 |
| Reversing Power Base Compatibility | Reversing power base LU2B12FU, LU2B32FU, LU2B38FU |
| Rated Operational Voltage (Ue) | 690 V AC |
| Utilisation Category | AC-41, AC-43, AC-44 |
| Motor Power | 5.5 kW at 400-440 V AC, 5.5 kW at 500 V AC, 9 kW at 690 V AC |
| Rated Motor Current Adjustment Range (Ir) | 3-12 A |
| Thermal Overload Class | Class 10 |
| Tripping Threshold | 14.2 x Ir ± 20% |
| Phase Failure Sensitivity | Yes |
| Control Circuit Voltage (Uc) | 110-240 V AC, 110-220 V DC |
| Fixing Mode | Plug-in (front face) |
| Dimensions (W x H x D) | 45 x 66 x 60 mm |
| Rated Insulation Voltage (Ui) | 690 V |
| Ambient Air Temperature, Operation | -25...70 °C |
| Diagnostic Function | Thermal overload alarm usable locally via LUFDA module or remotely via LULC module, test push button for overload simulation |
| Reset | Manual reset |
Certifications & Standards
- CE
- UL
- CSA
- CCC
- EAC
- ASEFA
- ATEX
- Marine
- EN 60947-6-2
- IEC 60947-6-2
- UL 60947-4-1
- CSA C22.2 No 60947-4-1
Selection Notes
Set Ir within the 3-12 A window to match the motor's full-load current; Class 10 tripping at 14.2 x Ir covers standard-duty starts without needing a slower overload class. The advanced control unit adds a thermal overload alarm usable locally via a LUFDA module or remotely via a LULC module, and a test push button for overload simulation on top of the same overload, short-circuit, phase-failure and earth-fault protection as the standard unit in this current range - pick it when the panel needs that remote or local diagnostic signal.