- Home
- All Products
- ATS480D75Y, ATS480 Series Soft Starter, 37 kW, 75 A, 208 to 690V AC ATS480D75Y, ATS480 Series Soft Starter, 37 kW, 75 A, 208 to 690V AC
ATS480D75Y, ATS480 Series Soft Starter, 37 kW, 75 A, 208 to 690V AC
€1.600,00
- Description
Schneider Electric ATS480 Soft Starter Series – Overview
Schneider Electric ATS480 soft starters are advanced motor control solutions designed to deliver smooth, controlled starting and stopping of asynchronous motors in demanding industrial environments. The ATS480 series focuses on reducing mechanical stress, limiting inrush current, and improving overall system reliability through intelligent control and integrated motor protection features. With robust design, advanced diagnostics, and flexible communication options, Schneider ATS480 soft starters are well suited for applications such as pumps, fans, compressors, conveyors, and process machinery. The ATS480 series supports energy-efficient motor operation while enhancing equipment lifespan and process stability across a wide range of industrial sectors.
Product Description: Schneider Electric ATS480D75Y
The Schneider Electric ATS480D75Y is an ATS480-series soft starter rated for 75 A (normal duty) and designed for three-phase supply voltages from 208 V to 690 V. Depending on supply voltage and wiring (inline or delta), this model covers a wide motor power range — commonly specified as 18.5 kW at 230 V (inline normal duty) up to 55 kW at 400–690 V when connected in the motor delta (normal duty). The ATS480D75Y provides torque control (TCS) for controlled acceleration and deceleration, and includes motor overload protection. It supports dynamic braking and DC injection for stopping high-inertia loads and can be installed inline or wired to the motor delta to reduce operational current. With IP20 protection and conformity to IEC/EN 60947-4-1, the ATS480D75Y is intended for process and infrastructure applications such as pumps, compressors, conveyors and other industrial motor loads that require reduced mechanical stress, limited inrush, and enhanced start/stop control.
Key Soft Starter Attributes
- Rated Operational Current (Ie): 75 A (normal duty); 62 A (heavy duty at 40 °C)
- Motor Power Range: Typical: 18.5 kW at 230 V (inline normal duty) up to 55 kW (400–690 V, delta/inline normal duty) — see model wiring and duty class for exact values
- Supply Voltage: 208 V to 690 V AC, 50/60 Hz
- Control Method: Torque control (TCS) with soft start/stop, dynamic braking and DC injection for stopping
- Built-in Bypass: No (internal bypass not included)
- Motor Protection Functions: Integrated motor overload protection
- Communication Interfaces: Optional communication modules available (Modbus TCP/EtherNet‑IP, Profibus DP, CANopen, PROFINET) as add‑on cards
- Enclosure / Protection Class: IP20
Frequently Asked Questions (FAQ)
What supply voltages does the ATS480D75Y support?
The ATS480D75Y supports 3-phase supply voltages from 208 V to 690 V AC at 50/60 Hz.
What is the rated current and how does duty class affect it?
Rated operational current is 75 A in normal duty. For heavy-duty applications the rated current is reduced (specified as 62 A at 40 °C for heavy duty).
Can this model stop high-inertia loads?
Yes — the ATS480D75Y supports dynamic braking and DC injection to efficiently stop high-inertia applications.
Does the ATS480D75Y include an internal bypass or fieldbus connectivity?
There is no internal bypass on this model. Communication modules (Profibus DP, Modbus TCP/EtherNet‑IP, CANopen, PROFINET, etc.) are available as optional add-on cards.