- ABB 1SDA070742R1 E1.2B 800 Ekip Dip LSI 3p F F 800A 42kA 3-Pole Fixed Air Circuit Breaker ABB 1SDA070742R1 E1.2B 800 Ekip Dip LSI 3p F F 800A 42kA 3-Pole Fixed Air Circuit Breaker
ABB 1SDA070742R1 E1.2B 800 Ekip Dip LSI 3p F F 800A 42kA 3-Pole Fixed Air Circuit Breaker
$2,161.72
- Description
The ABB E1.2B 800 Ekip Dip LSI 3p F F (SKU: 1SDA070742R1) is a 3-pole, fixed-mounted air circuit breaker from the Emax2 E1.2 series, rated at 800 A with a breaking capacity of 42 kA at 400 V AC. Equipped with the Ekip Dip LSI trip unit, this ACB delivers reliable overload (L), short-circuit (S), and instantaneous (I) protection for demanding low-voltage power distribution systems.
Technical Specifications
| Catalog Number | E1.2B 800 Ekip Dip LSI 3p F F |
| SKU | 1SDA070742R1 |
| Brand | ABB |
| Series | Emax2 E1.2 |
| Model Number | E1.2B |
| EAN / Barcode | 8015644745929 |
| Rated Current | 800 A |
| Breaking Capacity (Icu @ 400 V AC) | 42 kA |
| Number of Poles | 3 |
| Trip Unit | Ekip Dip LSI |
| Protection Functions | L (overload), S (short-circuit), I (instantaneous) |
| Mounting Type | Fixed (F F) |
| Dimensions (W × H × D) | 210 mm × 296 mm × 183 mm |
| Weight | 15.75 kg |
| Product Type | Air Circuit Breaker (ACB) |
Certifications & Standards
- CE: Compliant with EU low-voltage and electromagnetic compatibility directives
- RoHS: Compliant with EU Directive 2011/65/EU on restriction of hazardous substances
- Amendment 2015/863: Compliant with EU RoHS Amendment extending restricted substance list
- REACH: Compliant with EU REACH regulation (EC No 1907/2006) on chemical safety
- IEC: Designed and tested to IEC standards for low-voltage switchgear and controlgear
- UL 2799: Listed under UL 2799 for electrical systems performance
- ATEX: Suitable for use in potentially explosive atmospheres per ATEX directive
- CSA: Certified to Canadian Standards Association requirements
- VDE: Tested and certified by VDE (Verband der Elektrotechnik) to German/European standards
- WEEE: Registered under the Waste Electrical and Electronic Equipment directive for responsible end-of-life disposal
Applications & Use Cases
- Main and sub-main incomer protection in low-voltage switchboards and motor control centres (MCCs)
- Bus-tie and feeder protection in industrial power distribution panels
- Generator and transformer outgoing protection in commercial and industrial installations
- Data centres, infrastructure projects, and heavy industrial facilities requiring reliable 800 A overcurrent protection
- Applications in potentially explosive environments (ATEX-rated installations)
Frequently Asked Questions
What is the breaking capacity of the E1.2B 800 Ekip Dip LSI 3p F F?
The rated ultimate breaking capacity (Icu) is 42 kA at 400 V AC, making it suitable for high fault-level industrial networks.
What protection functions does the Ekip Dip LSI trip unit provide?
The Ekip Dip LSI trip unit provides Long-time (L) overload protection, Short-time (S) delayed short-circuit protection, and Instantaneous (I) short-circuit protection — configurable via DIP switches on the trip unit face.
Is the 1SDA070742R1 withdrawable or fixed?
This unit is fixed-mounted (F F designation). A withdrawable version is available separately in the Emax2 range.
What are the physical dimensions and weight?
The breaker measures 210 mm (W) × 296 mm (H) × 183 mm (D) and weighs 15.75 kg.