- Description
Siemens 3RW55 Soft Starter Series – Overview
Siemens 3RW55 soft starters are heavy-duty motor starting solutions designed for high-power industrial applications requiring robust and reliable control of three-phase asynchronous motors. The 3RW55 series focuses on reducing mechanical stress, limiting inrush current, and supporting very high motor power ratings with advanced motor protection and monitoring capabilities. With a rugged design and suitability for demanding operating conditions, Siemens 3RW55 soft starters are well suited for large pumps, compressors, crushers, conveyors, mills, and other heavy industrial machinery where dependable motor starting and long-term reliability are critical.
Product Description: 3RW5516-1HA14
The Siemens 3RW5516-1HA14 is a SIRIUS 3RW55 high-performance digital soft starter rated for 32 A operational current and designed for supply voltages from 200 to 480 V AC. Its control supply is 110–250 V AC, and it supports three-phase torque control for smoother acceleration and reduced mechanical stress. At standard wiring (inline), the unit is specified for motor power ratings of 7.5 kW at 230 V and 15 kW at 400 V; when used inside-delta the applicable ratings reach 15 kW at 230 V and 22 kW at 400 V. The device includes an internal bypass, integrated motor overload protection and a removable HMI with colour display for measurement and diagnostics. Optional plug-in communication modules (PROFINET, PROFIBUS, Modbus TCP) allow integration into automation networks. Typical applications are large pumps, compressors, conveyors and other heavy-duty industrial motors that benefit from adjustable starting current/torque control, reduced inrush, condition monitoring and simplified commissioning.
Key Soft Starter Attributes
| Rated operational current (Ie) | 32 A |
|---|---|
| Supply voltage | 200 – 480 V AC |
| Motor power range | Inline: 7.5 kW (230 V) / 15 kW (400 V); Inside‑delta: 15 kW (230 V) / 22 kW (400 V) |
| Control method | Three-phase torque control (adjustable start current / torque) |
| Built-in bypass | Yes (internal bypass) |
| Motor protection functions | Integrated motor overload protection; adjustable monitoring and condition monitoring features |
| Communication interfaces | Optional plug-in modules: PROFINET, PROFIBUS, Modbus TCP |
| Enclosure / protection class | IP00 |