- Description
The Siemens 6XV1878-2AU10 is a 1000 m reel of IE FastConnect TP Standard GP cable, a Category 6A shielded twisted-pair installation cable with 4x2 AWG24 cores for fixed Industrial Ethernet wiring. It supports 100BaseTX and 1000BaseT runs to 100 m and 10GBase-T to 90 m, with PoE/PoE+/PoE++ capability and a -40 to +85 °C operating range.
Technical Specifications
| Order Number (MLFB) | 6XV1878-2AU10 |
| EAN | 4019169857406 |
| Brand | Siemens |
| Series | SIMATIC NET |
| Product Type Designation | IE FC TP Standard Cable GP 4x2, AWG24, Type C |
| Product Description | Shielded TP installation cable (8-wire), preferred length, unassembled |
| Suitability | Standard cable with rigid cores for fast, permanent installation |
| Cable Designation | SF/UTP, 2YH(ST)CY 4x2x0.5/1.0 GN |
| Reel Length | 1000 m, sold by the meter |
| Attenuation at 10 MHz (max) | 0.058 dB/m |
| Attenuation at 100 MHz (max) | 0.191 dB/m |
| Attenuation at 250 MHz (max) | 0.311 dB/m |
| Attenuation at 300 MHz (max) | 0.343 dB/m |
| Attenuation at 500 MHz (max) | 0.453 dB/m |
| Impedance (1-100 MHz) | 100 Ω |
| Near-End Crosstalk per Length (1-100 MHz) | 0.453 dB/m |
| Near-End Crosstalk per Length (1-250 MHz) | 0.393 dB/m |
| Near-End Crosstalk per Length (1-300 MHz) | 0.381 dB/m |
| Near-End Crosstalk per Length (1-500 MHz) | 0.348 dB/m |
| Coupling Loss at 30-100 MHz (min) | 80 dB |
| Transfer Impedance per Length at 10 MHz | 20 mΩ/m |
| Loop Resistance per Length (max) | 190 mΩ/m |
| Insulation Resistance Coefficient | 5000 GΩ·m |
| Operating Voltage (RMS / max) | 80 V |
| NVP Value | 67 percent |
| Number of Electrical Cores | 8 |
| Shield Design | SF/UTP, overlapped aluminum-clad foil with braided tinned-copper shield |
| FastConnect Termination | Yes |
| Conductor Diameter (AWG24) | 0.51 mm |
| Wire Insulation Diameter | 1 mm |
| Inner Sheath Diameter | 6.1 mm |
| Cable Sheath Diameter | 8 mm |
| Sheath Diameter Tolerance | 0.2 mm |
| Wire Insulation Material | Polyethylene (PE) |
| Inner Sheath Material | FRNC |
| Cable Sheath Material | PVC |
| Data Wire Colors | White-blue/blue, white-orange/orange, white-green/green, white-brown/brown |
| Cable Sheath Color | Green |
| Bending Radius, Single Bend (min) | 24 mm |
| Bending Radius, Multiple Bends (min) | 40 mm |
| Maximum Tensile Load | 100 N |
| Weight per Length | 76 kg/km |
| Net Weight (1000 m reel) | 81.65 kg |
| Operating Temperature | -40 to +85 °C |
| Storage Temperature | -40 to +80 °C |
| Transport Temperature | -40 to +80 °C |
| Installation Temperature | -40 to +80 °C |
| Fire Behavior | Flame resistant per IEC 60332-3-24, Category C |
| Burning Behavior Class (EN 13501-6) | Eca |
| Chemical Resistance to Mineral Oil | Oil resistant per IEC 60811-2-1 (4h/70°C) |
| Chemical Resistance to Grease | Conditional resistance |
| Chemical Resistance to Water | Conditional resistance |
| UV Resistance | Resistant |
| PoE / PoE+ / PoE++ Capability | Yes |
| Silicone-Free | Yes |
| Max. Segment Length, 100BaseTX / 1000BaseT | 100 m |
| Max. Segment Length, 10GBase-T | 90 m |
| Test Voltage AC, Core-to-Core / Core-Shield | 2000 V |
| UL/ETL Listing (300 V) | c(UL)us, CMG, AWM-Style 21500, cRU AWM I A/B 60°C 300V FT2 |
| Structured Cabling Standard | Cat6A |
| Air Pollution Resistance (ANSI/ISA-71.04) | G3 |
| Country of Origin | Germany |
Certifications & Standards
- EAC
- CE
- RoHS
- ANSI/TIA-EIA 568-B.2 Cat.5e
- IEC 61784-5-2-CP 2/2
Selection Notes
This GP-jacketed 1000 m reel is the general-purpose Cat6A option for fixed indoor Industrial Ethernet runs — the PVC outer sheath and FRNC inner sheath suit standard cable tray and duct installation rather than direct burial or high-flex use. Because it is FastConnect-terminated (field-installable RJ45 connectors), buy the reel and terminate on site rather than ordering pre-assembled patch cords; the 90 m 10GBase-T reach and PoE++ rating cover most cabinet-to-device runs, so route the last few meters with a shorter pre-terminated cord where flex life or connector count matters more than bulk length.