- Home
- Siemens
- Siemens 6XV1873-3AT10 SIMATIC NET FO Standard Cable 50/125 100m 4xBFOC Network Cable Siemens 6XV1873-3AT10 SIMATIC NET FO Standard Cable 50/125 100m 4xBFOC Network Cable
Siemens 6XV1873-3AT10 SIMATIC NET FO Standard Cable 50/125 100m 4xBFOC Network Cable
Get Quote
- Description
The Siemens SIMATIC NET FO Standard Cable (6XV1873-3AT10) is a 100 m preassembled glass fiber-optic cable with four BFOC connectors, built on 50/125 µm OM2 multimode gradient fiber for Industrial Ethernet and PROFIBUS links. It carries UL approval for indoor/outdoor runs and supports 100BaseFX segments up to 5000 m or 1000BaseSX segments up to 750 m.
Technical Specifications
| SKU (Order No.) | 6XV1873-3AT10 |
| Brand | Siemens |
| Series | SIMATIC NET |
| EAN | 4019169850568 |
| Product type designation | FO Standard Cable GP |
| Cable designation | AT-W(ZN)YY 2x1 G 50/125 OM2++ |
| Wire length | 100 m |
| Version | Assembled with four BFOC connectors |
| Fiber type | Multi-mode gradient fiber 50/125 µm, OM2 |
| Number of FO cores | 2 |
| Attenuation at 850 nm, max. | 2.7 dB/km |
| Attenuation at 1300 nm, max. | 0.7 dB/km |
| Bandwidth length product at 850 nm | 600 GHz·m |
| Bandwidth length product at 1300 nm | 1200 GHz·m |
| Max. wire length, 100BaseFX | 5000 m |
| Max. wire length, 1000BaseSX | 750 m |
| Max. wire length, 1000BaseLX | 2000 m |
| Max. wire length, PROFIBUS | 3000 m |
| Bending radius, single bend, min. | 45 mm |
| Bending radius, multiple bends, min. | 65 mm |
| Tensile load during installation, short-term | 1200 N |
| Ambient temperature, operation | -25 to +80°C |
| Fire behavior | Flame-resistant per IEC 60332-1-2 / IEC 60332-3-22 (Cat. A) |
| Protection class | IP20 |
| Net weight | 4.0 kg |
Certifications & Standards
- RoHS
Selection Notes
At 100 m this preassembled length covers longer cabinet-to-cabinet or inter-floor runs in one continuous pull, avoiding a field-terminated splice that the shorter 50 m variant would need on the same distance. The four-BFOC termination pre-configures the cable as two independent fiber pairs, so a single reel can serve one Industrial Ethernet or PROFIBUS link, or two shorter segments from a common patch panel. The 45 mm single-bend radius and 1200 N short-term tensile rating are the limits to check against cable tray routing before ordering, since exceeding either during pulling degrades the attenuation figures.
Applications
Fiber backbone links between Industrial Ethernet switches or PROFIBUS segments across separate control cabinets, floors, or buildings where copper runs would exceed distance or EMI limits. UL-listed jacket allows the same cable type indoors and in protected outdoor runs.