The Schneider Electric BLRCS025A030B40 is an EasyLogic power factor correction capacitor rated 2.5 kvar at 400 V, 50 Hz (3 kvar at 60 Hz). Built for standard operating conditions with network harmonic content up to 10 %, it corrects the reactive power drawn by stable, largely linear loads, cutting the current an installation pulls from the supply and avoiding low-power-factor penalties on the utility bill.
Technical Specifications
| Reference | BLRCS025A030B40 |
| Brand | Schneider Electric |
| Range | EasyLogic |
| Product or component type | Standard duty capacitor |
| Rated reactive power at 400 V, 50 Hz | 2.5 kvar |
| Rated reactive power at 400 V, 60 Hz | 3 kvar |
| Rated voltage | 380…415 V AC 50/60 Hz |
| Rated frequency | 50/60 Hz |
| Network harmonic content | <= 10 % |
| Continuous overcurrent capacity | 1.5 x In |
| Maximum permissible voltage | 1.1 x Un (8 hours over 24 hours) |
| Inrush current | 200 x In |
| Losses (dielectric / total) | < 0.2 W/kvar dielectric, < 0.5 W/kVAr total |
| Capacitance tolerance | -5 % to 10 % |
| Maximum switching operations per year | 5000 |
| Service life | 100000 h |
| Connections - terminals | Double Faston terminal |
| Mounting mode | Vertical |
| Dimensions (diameter x height) | 50 mm x 245 mm |
| Net weight | 0.7 kg |
| IP degree of protection | IP20 |
| Operating altitude | 2000 m |
| Temperature class | D |
| Ambient air temperature for operation | -25...55 °C |
| Relative humidity | 95 % |
Certifications & Standards
- IEC 60831-1
- IEC 60831-2
Selection Notes
At 2.5 kvar and 400 V, the BLRCS025A030B40 fits a step within an automatic power factor correction bank sized for stable, largely linear loads. Move to the next EasyLogic step in the 400 V family as the compensated reactive load grows, or down a step for finer switching granularity. Because continuous overcurrent capacity is limited to 1.5 x In, keep this variant on networks where harmonic content stays at or below 10%; on busbars with higher distortion from variable-speed drives or rectifiers, the VarPlus Can HDuty range with its 1.8 x In rating is the right choice instead.