- Home
- Power Factor Correction
- Schneider Electric BLRCH120A144B57 VarPlus Can HDuty 12/14.4 kvar 575 V Power Factor Correction Capacitor Schneider Electric BLRCH120A144B57 VarPlus Can HDuty 12/14.4 kvar 575 V Power Factor Correction Capacitor
Schneider Electric BLRCH120A144B57 VarPlus Can HDuty 12/14.4 kvar 575 V Power Factor Correction Capacitor
Schneider Electric BLRCH120A144B57 VarPlus Can HDuty 12/14.4 kvar 575 V Power Factor Correction Capacitor
Get Quote
- Description
The Schneider Electric BLRCH120A144B57 is a VarPlus Can HDuty power factor correction capacitor rated 12 kvar at 575 V, 50 Hz (14.4 kvar at 60 Hz), built for networks with up to 20% harmonic content where the circulating harmonic current requires an increased rated current capacitor rather than a standard-duty unit. Fastening is by clamptite terminal.
Technical Specifications
| SKU | BLRCH120A144B57 |
| Brand | Schneider Electric |
| Range | PowerLogic |
| Series | VarPlus Can HDuty |
| Rated reactive power | 12 kvar at 575 V, 50 Hz / 14.4 kvar at 575 V, 60 Hz |
| Rated voltage | 575 V AC, 50/60 Hz |
| Network frequency | 50 Hz / 60 Hz |
| Network harmonic content | <= 20 % |
| Continuous overcurrent capacity | 1.8 x In |
| Maximum permissible voltage | 1.1 x Un (8 hours in every 24 hours) |
| Inrush current | 250 x In |
| Capacitance tolerance | -5 % to +10 % |
| Dielectric losses | < 0.2 W/kvar |
| Power losses | < 0.5 W/kVAr |
| Maximum switching operations | 7000 per year |
| Service life | 130000 hours |
| Dielectric / impregnation | Metallized polypropylene film (Zn/Al alloy); non-PCB dry PUR resin, biodegradable |
| Connections | ClampTite terminal |
| Mounting mode | Upright or horizontal |
| Diameter x Height | 116 mm x 242 mm |
| Weight | 2.5 kg |
| IP rating | IP20 |
| Temperature class | D |
| Operating temperature | -25 to 55 C |
| Standards | IEC 60831-1, IEC 60831-2 |
Certifications & Standards
- IEC 60831-1
- IEC 60831-2
Selection Notes
Match the BLRCH120A144B57 to the switchboard's nominal voltage (575 V) and the reactive power step the correction bank needs -- 12 kvar at 50 Hz, 14.4 kvar at 60 Hz. The 575 V rating and larger 116 mm can (2.5 kg) suit North American 600 V-class distribution boards running a 575 V nominal supply. The 1.8 x In continuous overcurrent capacity and <=20% permissible network harmonic content make HDuty construction the right choice where variable-speed drives or other non-linear loads circulate harmonic current; on a clean network a VarPlus Can SDuty unit would be the lower-cost alternative.