- Home
- New Arrivals
- ATS22C41Q, Altistart 22 Series Soft Starter, 220 kW, 410 A, 230 to 440V AC ATS22C41Q, Altistart 22 Series Soft Starter, 220 kW, 410 A, 230 to 440V AC
ATS22C41Q, Altistart 22 Series Soft Starter, 220 kW, 410 A, 230 to 440V AC
$3,511.46
- Description
Schneider Electric ATS22 Soft Starter Series – Overview
Schneider Electric ATS22 soft starters are compact and reliable motor starting solutions designed for smooth acceleration and deceleration of asynchronous motors in standard industrial applications. The ATS22 series focuses on reducing mechanical stress, limiting starting current, and simplifying motor starting without advanced digital control requirements. With a proven design and straightforward configuration, ATS22 soft starters are commonly used for pumps, fans, compressors, conveyors, and general-purpose machinery where controlled motor starting is required.
Product Description: ATS22C41Q
The Schneider ATS22C41Q Altistart 22 soft starter is specified for heavy-duty three-phase industrial motor starting with a nominal operational current of 410 A. It supports common supply voltages in industrial facilities (230…440 VAC, 50/60 Hz) and is rated for motor powers up to 110 kW on 230 V and 220 kW on 400–440 V in standard configuration. This makes the ATS22C41Q suitable for medium to large asynchronous motors used in pumps, fans, compressors and conveyors where limiting inrush current and reducing mechanical stress are priorities. The unit implements torque/current-limited starting (current-limited start up to ≈3.5 × In) and includes an internal bypass contact to reduce heat and losses after start‑up. For application-level use, the ATS22C41Q includes integrated motor protection functions (thermal overload model, thermistor/PTC input, low-current and short-term overload detection) and offers field communication via Modbus where system integration or remote monitoring is required. These verified features make the ATS22C41Q a practical choice for procurement teams specifying a compact, straightforward motor soft starter for industrial motor control and reliable industrial motor starting.
Key Soft Starter Attributes
| Rated operational current (Ie) | 410 A |
|---|---|
| Motor power range | 110 kW @ 230 V; 220 kW @ 400–440 V (standard connection) |
| Supply voltage | 230…440 V AC (50/60 Hz) |
| Control method | Torque / current-limited start (approx. 3.5 × In) |
| Built-in bypass | Yes (internal bypass contact) |
| Motor protection functions | Integrated thermal overload model; PTC/thermistor input; low-current and momentary overload detection |
| Communication interfaces | Modbus (RTU) |