{"product_id":"siemens-6xv1878-5th10-ie-tp-cord-m12-180-rj45-180-1m","title":"Siemens 6XV1878-5TH10 SIMATIC NET IE TP Cord M12-180\/RJ45-180 1 m Cat6A Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5TH10 is a SIMATIC NET IE TP Cord M12-180\/RJ45-180, a pre-assembled Industrial Ethernet patch cable with an M12-180 X-coded connector at one end and an RJ45 connector at the other, on a 1 m S\/FTP Cat6A run. It carries PoE, PoE+, and PoE++, connecting an IP65\/IP67 M12 field device such as SCALANCE W or X to a standard IP20 RJ45 switch port.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5TH10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169857765\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/RJ45-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard for Structured Cabling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSuitability for Use\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor connecting Industrial Ethernet stations with an M12 interface (e.g. SCALANCE W and SCALANCE X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 10 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 100 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 300 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Factor at 600 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance (1-100 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 100 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 300 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk at 600 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance per Length (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVP Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e68%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign of Shield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil, sheathed in a protective braided shield of tinned copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Diameter (AWG26 insulated conductor)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Inner Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTolerance of Outer Diameter (Cable Sheath)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaterial of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Data Wire Insulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ewhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eColor of Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Load (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Installation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Mineral Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Grease\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChemical Resistance to Water\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Radiation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\/67 (M12), IP20 (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE++ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSilicon-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Listing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, 300 V rating, AWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertificate of Suitability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.076 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHS Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85444210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 1 m length gives enough slack to route from a nearby cabinet-mounted switch to an M12 gland entry without pulling the cable taut. Keep the IP20 RJ45 end inside the enclosure and the IP65\/IP67 M12 end in the field; for tighter same-cabinet jumpers or longer switch-to-panel runs, pick another length in the same M12-180\/RJ45-180 line.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474512155,"sku":"6XV1878-5TH10","price":76.29,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5th10-ie-tp-cord-m12-rj45-network-cable.png?v=1790183403","url":"https:\/\/stoklink.com\/products\/siemens-6xv1878-5th10-ie-tp-cord-m12-180-rj45-180-1m","provider":"Stoklink","version":"1.0","type":"link"}