{"product_id":"siemens-6xv1878-5he50-ie-tp-cord-m12-180-05m","title":"Siemens 6XV1878-5HE50 SIMATIC NET IE TP Cord M12-180\/M12-180 0.5m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1878-5HE50 preassembled IE TP Cord M12-180\/M12-180 is a 0.5 m Industrial Ethernet patch cord terminated with two X-coded M12 connectors, built for stations such as SCALANCE W or XP-200. It carries 100 Ω impedance, IP65\/IP67 sealing, and PoE\/PoE+\/PoE++ support across a -30 to +80 °C range, with Cat6A performance in a flexible PUR-jacketed S\/FTP construction.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6XV1878-5HE50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169856287\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord M12-180\/M12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eFlexible plug-in cable (8-wire), prefabricated with two IE FC M12 connectors 4x2, X-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability\u003c\/td\u003e\n\u003ctd\u003eConnecting Industrial Ethernet stations with an M12 interface, e.g. SCALANCE W and XP-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Designation\u003c\/td\u003e\n\u003ctd\u003eS\/FTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Connections\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 10 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 100 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 300 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.402 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 600 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance (1-100 MHz)\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk per Length at 100 MHz\u003c\/td\u003e\n\u003ctd\u003e0.724 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk per Length at 300 MHz\u003c\/td\u003e\n\u003ctd\u003e0.653 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNear-End Crosstalk per Length at 600 MHz\u003c\/td\u003e\n\u003ctd\u003e0.608 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoupling Loss at 30-100 MHz (min)\u003c\/td\u003e\n\u003ctd\u003e80 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Resistance per Length (max)\u003c\/td\u003e\n\u003ctd\u003e290 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance Coefficient\u003c\/td\u003e\n\u003ctd\u003e5000 GΩ·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (RMS)\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNVP Value\u003c\/td\u003e\n\u003ctd\u003e68 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Cores\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Design\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, overlapped aluminum-clad foil with braided tinned-copper shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Diameter (AWG26)\u003c\/td\u003e\n\u003ctd\u003e0.48 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Diameter\u003c\/td\u003e\n\u003ctd\u003e1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Sheath Diameter\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Diameter\u003c\/td\u003e\n\u003ctd\u003e6.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSheath Diameter Tolerance\u003c\/td\u003e\n\u003ctd\u003e0.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Material\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Wire Colors\u003c\/td\u003e\n\u003ctd\u003eWhite\/blue, white\/orange, white\/green, white\/brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Single Bend (min)\u003c\/td\u003e\n\u003ctd\u003e32.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Multiple Bends (min)\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Tensile Load\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e45 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.065 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug Interlock\u003c\/td\u003e\n\u003ctd\u003eScrewed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlug-In Connection Design\u003c\/td\u003e\n\u003ctd\u003eM12-180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Coding\u003c\/td\u003e\n\u003ctd\u003eM12, X-coded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2, smoke density per IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Mineral Oil\u003c\/td\u003e\n\u003ctd\u003eOil resistant per DIN EN 60811-2-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Grease\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Water\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Resistance\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP65, IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHalogen-Free\u003c\/td\u003e\n\u003ctd\u003eYes, per IEC 60754-1, IEC 61034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoE \/ PoE+ \/ PoE++ Capability\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicone-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/ETL Listing (300 V)\u003c\/td\u003e\n\u003ctd\u003eAWM Style 21815, Wiring Harness\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Suitability\u003c\/td\u003e\n\u003ctd\u003eISO\/IEC 11801-1, IEC 61035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructured Cabling Standard\u003c\/td\u003e\n\u003ctd\u003eCat6A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 0.5 m cord bridges a slightly wider gap than the 0.3 m version — a typical use is linking a SCALANCE W unit to a nearby junction box or the next DIN-rail position — while adding only marginal attenuation, since 0.28 dB\/m at 100 MHz applies equally across the family. Because connector type, shield design, and IP rating are identical across the 0.3 m, 0.5 m, and 1 m variants, base the length choice solely on the measured distance between the two M12 ports rather than on any performance difference.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959474118939,"sku":"6XV1878-5HE50","price":84.29,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1878-5he50-ie-tp-cord-m12-180-0-5m.png?v=1790183347","url":"https:\/\/stoklink.com\/products\/siemens-6xv1878-5he50-ie-tp-cord-m12-180-05m","provider":"Stoklink","version":"1.0","type":"link"}