{"product_id":"siemens-6xv1875-5cn10-antenna-cable-n-connect-rsma-10m","title":"Siemens 6XV1875-5CN10 SIMATIC NET Antenna Cable N-Connect\/R-SMA m\/m 10m IWLAN Antenna Cable","description":"\u003cp\u003eThe Siemens 6XV1875-5CN10 is a 10 m antenna connection cable with N-Connect\/R-SMA male\/male plugs, a flexible 50 Ω cable for connecting an antenna to an access point or client radio. It covers 0 to 6000 MHz, has a typical 0.53 dB\/m attenuation at 2.4 GHz, and carries IP68 protection when mated.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1875-5CN10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169852647\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAntenna Connection Cable N-Connect\/R-SMA Plug\/Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-Connect\/R-SMA male\/male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 6000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 2.4 GHz (typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.53 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 5.2 GHz (typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.83 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 5.85 GHz (typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.89 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReturn Loss (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharacteristic Impedance (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance at 1 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 pF\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBraided shield of tin-plated copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInner Conductor Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.3 mm ± 0.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Thickness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInner Conductor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFRNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePastel turquoise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Tensile Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight (this length)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (operation \/ storage \/ transport)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (installation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOil Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP68 (when plugged in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 1685 (Vertical tray), UL 1581 Sec. 1090 (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 10 m length reaches an externally mounted antenna from an indoor access point or client radio without an in-line splice, terminated N-Connect\/R-SMA for direct connection to an R-SMA antenna port on the AP or client. Over the full 10 m, typical attenuation of 0.53 dB\/m at 2.4 GHz adds up to roughly 5.3 dB of loss, so this run length should be weighed against antenna gain when planning the link budget. Confirm the access point or client radio's antenna connector type before ordering, since this cable's R-SMA end will not mate with an N-Connect port.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed to connect access points or client radios with an R-SMA antenna port to an externally mounted, N-Connect terminated antenna or RCoax feed line in IWLAN installations. The IP68-when-plugged rating and -40 to +80°C operating range suit outdoor and harsh-environment antenna runs on mobile equipment, cranes, and AGVs.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959473955099,"sku":"6XV1875-5CN10","price":94.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1875-5cn10-antenna-cable-n-connect-rsma-10m.png?v=1789715281","url":"https:\/\/stoklink.com\/products\/siemens-6xv1875-5cn10-antenna-cable-n-connect-rsma-10m","provider":"Stoklink","version":"1.0","type":"link"}