{"product_id":"siemens-6xv1875-5ch10-antenna-cable-n-connect-rsma-1m","title":"Siemens 6XV1875-5CH10 SIMATIC NET N-Connect\/R-SMA Antenna Connecting Cable 1 m Antenna Cable","description":"\u003cp\u003eThe Siemens 6XV1875-5CH10 is a preassembled N-Connect\/R-SMA male\/male antenna connecting cable, 1 m long, with 50 ohm impedance and IP68 protection when mated. It links a SIMATIC NET antenna to a SCALANCE access point or client that carries an R-SMA port, covering the 0 to 6000 MHz band with a minimum return loss of 23 dB.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6XV1875-5CH10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4018359300654\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eAntenna connection cable N-Connect\/RSMA plug\/plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eConnecting cable for SIMATIC NET antennas, preassembled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for Use\u003c\/td\u003e\n\u003ctd\u003eFlexible connecting cable for connecting an antenna to an access point\/client\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eN-Connect \/ R-SMA, male\/male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Length\u003c\/td\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Electrical Connections\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Frequency\u003c\/td\u003e\n\u003ctd\u003e0 to 6000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 2.4 GHz (typical)\u003c\/td\u003e\n\u003ctd\u003e0.53 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 5.2 GHz (typical)\u003c\/td\u003e\n\u003ctd\u003e0.83 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 5.85 GHz (typical)\u003c\/td\u003e\n\u003ctd\u003e0.89 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn Loss (min)\u003c\/td\u003e\n\u003ctd\u003e23 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance\u003c\/td\u003e\n\u003ctd\u003e50 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance per Length at 1 kHz\u003c\/td\u003e\n\u003ctd\u003e82 pF\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Propagation Velocity\u003c\/td\u003e\n\u003ctd\u003e82 percent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Design\u003c\/td\u003e\n\u003ctd\u003eBraided shield, tin-plated copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Conductor Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e1.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e3.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e6.3 mm, plus\/minus 0.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Thickness\u003c\/td\u003e\n\u003ctd\u003e0.76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Conductor Material\u003c\/td\u003e\n\u003ctd\u003eCu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Material\u003c\/td\u003e\n\u003ctd\u003ePolyethylene foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Material\u003c\/td\u003e\n\u003ctd\u003eFRNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003ePastel turquoise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Single Bend (min)\u003c\/td\u003e\n\u003ctd\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Multiple Bends (min)\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Tensile Load\u003c\/td\u003e\n\u003ctd\u003e80 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e75 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Storage\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Transport\u003c\/td\u003e\n\u003ctd\u003e-40 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Installation\u003c\/td\u003e\n\u003ctd\u003e-25 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Mineral Oil\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Resistance\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class (plugged in)\u003c\/td\u003e\n\u003ctd\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHalogen-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicon-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior Standard\u003c\/td\u003e\n\u003ctd\u003eUL 1685 (Vertical Tray), UL 1581 Sec. 1090 (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAC Approval\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Conformity\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85442000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.115 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eSK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 1 m, this cable suits an antenna mounted on an adjacent panel or the outside of the same cabinet as the access point or client. The 0.3 m version covers tighter runs, and the 2 m version reaches further; pick by the actual measured run, since the 0.53-0.89 dB\/m attenuation across 2.4\/5.2\/5.85 GHz adds up with length and reduces the link budget at the radio.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFlexible RF jumper for connecting a SIMATIC NET antenna to a SCALANCE W access point or client fitted with an R-SMA connector, in IWLAN installations such as RCoax-fed cells and other access-point antennas.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959473758491,"sku":"6XV1875-5CH10","price":51.22,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1875-5ch10-antenna-cable-n-connect-rsma.png?v=1790183275","url":"https:\/\/stoklink.com\/products\/siemens-6xv1875-5ch10-antenna-cable-n-connect-rsma-1m","provider":"Stoklink","version":"1.0","type":"link"}