{"product_id":"siemens-6xv1875-5an10-antenna-cable-n-connect-10m","title":"Siemens 6XV1875-5AN10 SIMATIC NET Antenna Cable N-Connect m\/m 10m IWLAN Antenna Cable","description":"\u003cp\u003eThe Siemens 6XV1875-5AN10 is a 10 m antenna connection cable with N-Connect male\/male plugs, a flexible 50 Ω cable for connecting an antenna or RCoax cable to a SCALANCE M\/W. It covers 0 to 6000 MHz, has a typical 0.53 dB\/m attenuation at 2.4 GHz, and carries IP68 protection when mated.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1875-5AN10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169852661\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAntenna Connection Cable N-Connect Plug\/Plug\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN-Connect\/N-Connect male\/male\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmission Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... 6000 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 2.4 GHz (typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.53 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 5.2 GHz (typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.83 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 5.85 GHz (typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.89 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReturn Loss (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e23 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharacteristic Impedance (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance at 1 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 pF\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBraided shield of tin-plated copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInner Conductor Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.3 mm ± 0.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Thickness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInner Conductor Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene foam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFRNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePastel turquoise\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Tensile Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight (this length)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (operation \/ storage \/ transport)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (installation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOil Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP68 (when plugged in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 1685 (Vertical tray), UL 1581 Sec. 1090 (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 10 m length reaches an antenna or RCoax feed point mounted further from the SCALANCE M\/W radio, such as on a mast or building roof, without an in-line splice. N-Connect male\/male on both ends means the cable requires a female bulkhead or antenna connector at each end. Over the full 10 m, typical attenuation of 0.53 dB\/m at 2.4 GHz adds up to roughly 5.3 dB of loss, so this run length should be weighed against antenna gain when planning the link budget. For a shorter run, choose the shorter length in the same cable range instead of coiling excess cable.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed to connect SCALANCE M\/W IWLAN or mobile radio devices to an externally mounted antenna or RCoax leaky feeder cable over longer runs such as mast or rooftop installations. The IP68-when-plugged rating and -40 to +80°C operating range suit outdoor and harsh-environment antenna runs on mobile equipment, cranes, and AGVs.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959473660187,"sku":"6XV1875-5AN10","price":93.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1875-5an10-antenna-cable-n-connect-10m.png?v=1789715275","url":"https:\/\/stoklink.com\/products\/siemens-6xv1875-5an10-antenna-cable-n-connect-10m","provider":"Stoklink","version":"1.0","type":"link"}