{"product_id":"siemens-6xv1873-6at20-fo-standard-cable-gp-200m","title":"Siemens 6XV1873-6AT20 SIMATIC NET FO Standard Cable GP 50\/125 200 m 4xSC Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1873-6AT20 FO Standard Cable GP is a preassembled 50\/125 um multimode fiber-optic cable, 200 m long, terminated at both ends with a pair of SC connectors and an insertion aid. Its OM2 gradient-index fiber carries Industrial Ethernet (100BaseFX, 1000BaseSX, 1000BaseLX) and PROFIBUS links, and the IP20 jacket is rated for indoor or outdoor installation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6XV1873-6AT20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169850896\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eFO Standard Cable GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eGlass fiber-optic cable, preferred length, preassembled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for Use\u003c\/td\u003e\n\u003ctd\u003eCable for installation indoors and outdoors, UL approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly\u003c\/td\u003e\n\u003ctd\u003ePreassembled with four SC connectors, insertion aid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Designation\u003c\/td\u003e\n\u003ctd\u003eAT-W(ZN)YY 2x1 G 50\/125 OM2++\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Length\u003c\/td\u003e\n\u003ctd\u003e200 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of FO Cores per Cable\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFibers per FOC Core\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003eMulti-mode gradient fiber 50\/125 um, OM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFOC Core Design\u003c\/td\u003e\n\u003ctd\u003eHollow core, filled, diameter 1400 um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber-Optic Cable Design\u003c\/td\u003e\n\u003ctd\u003esegmentable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 850 nm (max)\u003c\/td\u003e\n\u003ctd\u003e2.7 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 1300 nm (max)\u003c\/td\u003e\n\u003ctd\u003e0.7 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth Length Product at 850 nm\u003c\/td\u003e\n\u003ctd\u003e600 GHz x m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth Length Product at 1300 nm\u003c\/td\u003e\n\u003ctd\u003e1200 GHz x m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter of Optical Fiber\u003c\/td\u003e\n\u003ctd\u003e50 um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter of Optical Fiber Sheath\u003c\/td\u003e\n\u003ctd\u003e125 um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter of FOC Core Sheath\u003c\/td\u003e\n\u003ctd\u003e2.9 mm, plus\/minus 0.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Width\u003c\/td\u003e\n\u003ctd\u003e7.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Thickness\u003c\/td\u003e\n\u003ctd\u003e4.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFOC Cable Core Material\u003c\/td\u003e\n\u003ctd\u003eQuartz glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Fiber Sheath Material\u003c\/td\u003e\n\u003ctd\u003eQuartz glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFOC Core Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrain Relief Material\u003c\/td\u003e\n\u003ctd\u003eAramid fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFOC Core Sheath Color\u003c\/td\u003e\n\u003ctd\u003eorange\/black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003egreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Single Bend (min)\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Multiple Bends (min)\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile Load During Installation (short-term)\u003c\/td\u003e\n\u003ctd\u003e1200 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile Load During Operation (max)\u003c\/td\u003e\n\u003ctd\u003e500 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Term Shear Force per Length\u003c\/td\u003e\n\u003ctd\u003e600 N\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Shear Force per Length\u003c\/td\u003e\n\u003ctd\u003e400 N\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e40 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e8.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-25 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Storage\u003c\/td\u003e\n\u003ctd\u003e-25 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Transport\u003c\/td\u003e\n\u003ctd\u003e-25 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Installation\u003c\/td\u003e\n\u003ctd\u003e-5 to +50 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior\u003c\/td\u003e\n\u003ctd\u003eFlame-resistant acc. to IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Mineral Oil\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance to Grease\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Resistance\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicon-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Length, 100BaseFX (Industrial Ethernet)\u003c\/td\u003e\n\u003ctd\u003e5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Length, 1000BaseSX (Industrial Ethernet)\u003c\/td\u003e\n\u003ctd\u003e750 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Length, 1000BaseLX (Industrial Ethernet)\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Length with PROFIBUS\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL Approval\u003c\/td\u003e\n\u003ctd\u003ec(UL)us OFN FT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS Conformity\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85447000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eRoHS\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eUse the 200 m length for longer backbone segments between switch cabinets; the factory-terminated SC ends remove the need for field polishing and its associated loss variance. The same design is also supplied in 100 m, 150 m, and 300 m preassembled lengths - pick by the measured cable path, not straight-line distance, and keep the run within 5000 m for 100BaseFX, 750 m for 1000BaseSX, or 2000 m for 1000BaseLX at the intended Ethernet speed.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePreassembled SC-terminated multimode trunk cable for Industrial Ethernet backbones and PROFIBUS fiber-optic segments between control cabinets, machine sections, or buildings, in installations that need outdoor-rated, flame-resistant cabling without on-site fiber termination.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960048378139,"sku":"6XV1873-6AT20","price":1214.9,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1873-6at20-fo-standard-cable-gp-industrial-network-cable.png?v=1790183250","url":"https:\/\/stoklink.com\/products\/siemens-6xv1873-6at20-fo-standard-cable-gp-200m","provider":"Stoklink","version":"1.0","type":"link"}