{"product_id":"siemens-6xv1873-5ah50-fo-standard-cable-50-125-5m-lc","title":"Siemens 6XV1873-5AH50 SIMATIC NET FO Standard Cable GP 50\/125 5m LC Duplex Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1873-5AH50 is a 5 m FO Standard Cable GP, a 50\/125 µm multimode glass fiber-optic patch cable preassembled with two LC duplex connectors. It has 2.7 dB\/km maximum attenuation at 850 nm, a 600 GHz·m bandwidth-length product, IP20 protection, and UL approval for short Industrial Ethernet fiber jumper runs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1873-5AH50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169856683\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFO Standard Cable GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAT-W(ZN)YY 2x1 G 50\/125 OM2++\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssembly\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePreassembled with two LC duplex connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFiber Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-mode gradient fiber 50\/125 µm, OM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Fibers per FOC Core\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of FOC Cores per Cable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 850 nm (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.7 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 1300 nm (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.7 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth-Length Product at 850 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 GHz·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBandwidth-Length Product at 1300 nm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 GHz·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFOC Core Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHollow core, filled, diameter 1400 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSegmentable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Fiber Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Fiber Sheath Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFOC Core Sheath Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.9 mm ± 0.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Width\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Thickness\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFO Cable Core Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuartz glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Fiber Sheath Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuartz glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFOC Core Sheath Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStrain Relief Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAramid fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFOC Core Sheath Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOrange \/ Black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Load, Installation (short-term)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1200 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTensile Load, Operation (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Term Shear Force per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 N\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Shear Force per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 N\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight (this length)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (operation \/ storage \/ transport)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 ... +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (installation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 ... +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOil Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Length, 100BaseFX Industrial Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Length, 1000BaseSX Industrial Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e750 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Length, 1000BaseLX Industrial Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Length, PROFIBUS\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ec(UL)us OFN FT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eRoHS\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 5 m preassembled length with LC duplex connectors suits a short jumper run between a patch panel and a switch port, or between two adjacent cabinets, not a distribution run. LC duplex connectors have a smaller footprint than BFOC\/ST, so they suit high-port-density patch panels and switches. For a longer segment such as a machine-to-cabinet run, choose a longer pre-terminated length or a BFOC-terminated variant in the same cable range instead of field-splicing this jumper.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as a short fiber patch jumper linking Industrial Ethernet switches, media converters, or SFP ports within a cabinet or between adjacent racks where LC duplex connectivity is required. The -25 to +80°C operating range and IEC 60332-1-2 flame-resistant sheath suit control cabinet and patch panel routing.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960028979483,"sku":"6XV1873-5AH50","price":126.36,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1873-5ah50-fo-standard-cable-50-125-5m-lc.png?v=1789715178","url":"https:\/\/stoklink.com\/products\/siemens-6xv1873-5ah50-fo-standard-cable-50-125-5m-lc","provider":"Stoklink","version":"1.0","type":"link"}