{"product_id":"siemens-6xv1873-3an15-fo-standard-cable-50-125-15m","title":"Siemens 6XV1873-3AN15 SIMATIC NET FO Standard Cable 50\/125 4xBFOC 15 m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1873-3AN15 is a 15 m SIMATIC NET FO Standard Cable 50\/125, a glass multimode fiber-optic jumper preassembled with four BFOC connectors for 2x2 fiber-optic connections. Rated for indoor and outdoor installation, it carries a maximum attenuation of 2.7 dB\/km at 850 nm and supports Industrial Ethernet and PROFIBUS links over glass fiber where electrical isolation or long, EMI-immune runs are needed.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6XV1873-3AN15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eFO Standard Cable GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eGlass fiber-optic cable, preferred length, preassembled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for Use\u003c\/td\u003e\n\u003ctd\u003eCable for installation indoors and outdoors, UL approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion of Assembled FO Cable\u003c\/td\u003e\n\u003ctd\u003eAssembled with four BFOC connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Designation\u003c\/td\u003e\n\u003ctd\u003eAT-W(ZN)YY 2x1 G 50\/125 OM2++\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Length\u003c\/td\u003e\n\u003ctd\u003e15 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 850 nm (max)\u003c\/td\u003e\n\u003ctd\u003e2.7 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 1300 nm (max)\u003c\/td\u003e\n\u003ctd\u003e0.7 dB\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth Length Product at 850 nm\u003c\/td\u003e\n\u003ctd\u003e600 GHz·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandwidth Length Product at 1300 nm\u003c\/td\u003e\n\u003ctd\u003e1200 GHz·m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Fibers per FOC Core\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of FO Cores per FOC Cable\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFO Conductor Fiber\u003c\/td\u003e\n\u003ctd\u003eMulti-mode gradient fiber 50\/125 µm, OM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFOC Core Design\u003c\/td\u003e\n\u003ctd\u003eHollow core, filled, diameter 1400 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber-Optic Cable Design\u003c\/td\u003e\n\u003ctd\u003eSegmentable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Fiber Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e50 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Fiber Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e125 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFOC Core Sheath Outer Diameter\u003c\/td\u003e\n\u003ctd\u003e2.9 mm (tolerance 0.1 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Width\u003c\/td\u003e\n\u003ctd\u003e7.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Thickness\u003c\/td\u003e\n\u003ctd\u003e4.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber-Optic Cable Core Material\u003c\/td\u003e\n\u003ctd\u003eQuartz glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Fiber Sheath Material\u003c\/td\u003e\n\u003ctd\u003eQuartz glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFOC Core Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber-Optic Cable Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrain Relief Material\u003c\/td\u003e\n\u003ctd\u003eAramid fibers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFOC Core Sheath Color\u003c\/td\u003e\n\u003ctd\u003eorange\/black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003egreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Single Bend (min)\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Multiple Bends (min)\u003c\/td\u003e\n\u003ctd\u003e65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile Load, Installation (short-term)\u003c\/td\u003e\n\u003ctd\u003e1200 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile Load, Operation (max)\u003c\/td\u003e\n\u003ctd\u003e500 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Term Shear Force per Length\u003c\/td\u003e\n\u003ctd\u003e600 N\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Shear Force per Length\u003c\/td\u003e\n\u003ctd\u003e400 N\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e40 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\/Storage\/Transport\u003c\/td\u003e\n\u003ctd\u003e-25 ... +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Installation\u003c\/td\u003e\n\u003ctd\u003e-5 ... +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior\u003c\/td\u003e\n\u003ctd\u003eFlame-resistant per IEC 60332-1-2 and IEC 60332-3-22 (Cat. A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance (Mineral Oil \/ Grease)\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Resistance\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicon-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Wire Length, 100BaseFX (Industrial Ethernet)\u003c\/td\u003e\n\u003ctd\u003e5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Wire Length, 1000BaseSX (Industrial Ethernet)\u003c\/td\u003e\n\u003ctd\u003e750 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Wire Length, 1000BaseLX (Industrial Ethernet)\u003c\/td\u003e\n\u003ctd\u003e2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Wire Length, PROFIBUS\u003c\/td\u003e\n\u003ctd\u003e3000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL Listing\u003c\/td\u003e\n\u003ctd\u003ec(UL)us OFN FT4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169850506\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\u003cli\u003eRoHS\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 15 m, this cable reaches between separate cabinets or machine cells on the shop floor while staying well inside the 5000 m 100BaseFX and 3000 m PROFIBUS distance limits for this fiber type, so attenuation budget is not a constraint at this length. The glass OM2 core gives EMI immunity that a copper run cannot, which matters when the path crosses drive or welding cabling. Pick a shorter preassembled length for single-cabinet jumpers, or a longer one if the run must cross additional distance without a field splice.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFiber-optic PROFIBUS and Industrial Ethernet backbone links between SIMATIC NET components, and BFOC patch connections on switches or panels where a run crosses drive, welding, or other high-EMI cabling.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960009580827,"sku":"6XV1873-3AN15","price":154.81,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1873-3an15-fo-standard-cable-50-125-network-cable.png?v=1790183164","url":"https:\/\/stoklink.com\/products\/siemens-6xv1873-3an15-fo-standard-cable-50-125-15m","provider":"Stoklink","version":"1.0","type":"link"}