{"product_id":"siemens-6xv1870-3qe30-ie-tp-cord-rj45-rj45-cat6a","title":"Siemens 6XV1870-3QE30 SIMATIC NET IE TP Cord RJ45\/RJ45 Cat6a 0.3m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1870-3QE30 is a pre-assembled Industrial Ethernet TP cord with two latched RJ45 connectors, built to Cat6A S\/FTP shielding on a 0.3 m fixed length. It supports 10\/100\/1000\/10000 Mbit\/s links plus PoE, PoE+ and PoE++ power delivery, sized for short jumper connections inside a control cabinet or between adjacent switch ports.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Order Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1870-3QE30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169856539\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE TP Cord RJ45\/RJ45, 4x2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePatch cable, preassembled with two RJ45 connectors (10\/100\/1000\/10000 MB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP, LI 02YSCH 4x2x0.15 PIMF GN FRNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45, latched\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Connections\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCabling Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat6A (ISO\/IEC 11801-1, IEC 61035)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS\/FTP - overlapped aluminum-clad foil, braided tinned copper shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation @ 10 \/ 100 MHz (Max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.086 dB\/m \/ 0.28 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation @ 300 \/ 600 MHz (Max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.501 dB\/m \/ 0.735 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoupling Loss @ 30-100 MHz (Min.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Impedance per Length @ 10 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mOhm\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance per Length (Max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e290 mOhm\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVP Value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOuter Diameter, Cable Sheath\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (Min.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e31 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bend (Min.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e43.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating \/ Storage \/ Transport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 to +80 C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame-resistant acc. to IEC 60332-1-2, EN 60332-3-24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurning Behaviour Class (EN 13501-6)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOil Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOil-resistant acc. to IEC 60811-2-1 (4h\/70C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHalogen-Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, acc. to EN 60754-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE \/ PoE+ \/ PoE++ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes \/ Yes \/ Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Voltage, Core-to-Core \/ Core-Shield\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V \/ 1500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.022 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 0.3 m this is the shortest cord in the family, sized for jumpering between two devices mounted right next to each other, such as a switch and a media converter in the same cabinet, rather than a cabinet-to-field run. The Cat6A S\/FTP shield and PoE++ rating carry through the whole family; only the length changes, so pick 3 m, 20 m, 30 m or 35 m from this series once the actual cable path is longer than a jumper.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959965933851,"sku":"6XV1870-3QE30","price":25.04,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1870-3qe30-ie-tp-cord-rj45-rj45-cat6a.png?v=1790182118","url":"https:\/\/stoklink.com\/products\/siemens-6xv1870-3qe30-ie-tp-cord-rj45-rj45-cat6a","provider":"Stoklink","version":"1.0","type":"link"}