{"product_id":"siemens-6xv1840-2at10-ie-fc-tp-standard-cable-100m","title":"Siemens 6XV1840-2AT10 SIMATIC NET IE FC TP Standard Cable GP 2x2 Type A 100m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1840-2AT10 is a 100 m IE FC TP Standard Cable GP 2x2 (PROFINET Type A), a Cat5e-rated 4-wire shielded Industrial Ethernet cable with FastConnect termination for IE FC RJ45 plugs. It supports PoE and PoE+ operation, has a maximum loop resistance of 115 mΩ\/m, and is rated -40 to +75°C for permanent PROFINET installation runs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1840-2AT10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169856386\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIE FC TP Standard Cable GP 2x2 (Type A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSF\/UTP, 2YY (ST) CY 2x2x0,64\/1,5-100 GN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStructured Cabling Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCat5e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharacteristic Impedance (1-100 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 10 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.052 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 100 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.195 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNear-End Crosstalk (1-100 MHz)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Impedance at 10 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNVP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e69 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSF\/UTP, overlapped aluminum-clad foil, tinned copper braided shield\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastConnect Termination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWG22 Conductor Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Insulation Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInner Sheath Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.9 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5 mm ± 0.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Insulation Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInner Sheath Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Wire Insulation Colors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWhite \/ Yellow \/ Blue \/ Orange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Tensile Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight (this length)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (operation \/ storage \/ transport)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +75 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (installation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-3-24 (Category C) and UL 1685 (CSA FT 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurning Behavior Class (EN 13501-6)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOil Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant per IEC 60811-2-1 (4h\/70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE+ Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Length, 100BaseTX Industrial Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Voltage AC (core-to-core)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTest Voltage AC (core-to-shield)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Listing (300 V Rating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ec(ETL)us \/ CMG \/ (ETL)us PLTC\/ITC \/ Sun Res\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Style (600 V Rating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecRUus AWM 21694 AWM I A\/B 60°C 600V FT2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eChoose the 100 m length for a single continuous drop between a switch and a device rather than a field splice, since termination is FastConnect onto the IE FC RJ45 plug rather than a soldered joint. The Cat5e rating and 0.052 dB\/m attenuation at 10 MHz support 100BaseTX Industrial Ethernet runs up to 100 m, and PoE+ capability lets this cable carry both data and power to field devices such as IP cameras or WLAN access points on the same run. For a longer backbone segment, choose the longer-length variant in the same cable range instead of joining reels.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed for PROFINET and Industrial Ethernet device wiring in factory and process automation, connecting switches, PLCs, HMI panels, and PoE-powered field devices. The -40 to +60°C installation rating and IEC 60332-3-24 flame-resistant sheath suit cable trays, machine wiring, and panel-to-field runs.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959949287707,"sku":"6XV1840-2AT10","price":237.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1840-2at10-ie-fc-tp-standard-cable-100m.png?v=1789715159","url":"https:\/\/stoklink.com\/products\/siemens-6xv1840-2at10-ie-fc-tp-standard-cable-100m","provider":"Stoklink","version":"1.0","type":"link"}