{"product_id":"siemens-6xv1830-0eu10-profibus-fc-standard-cable-1000m","title":"Siemens 6XV1830-0EU10 SIMATIC NET PROFIBUS FC Standard Cable 1000 m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1830-0EU10 is a SIMATIC NET PROFIBUS FC Standard bus cable, a two-wire shielded design supplied as a 1000 m reel for FastConnect termination. It holds a 150 Ω rated impedance and 80 V RMS operating voltage, and its aluminum-clad foil plus braided copper-wire shield keeps it rated for continuous duty from -40 to +75°C.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6XV1830-0EU10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4019169851428\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eSK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS FC Standard Cable GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eStandard bus cable (2 wires), preferred length, not assembled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitability for Use\u003c\/td\u003e\n\u003ctd\u003eStandard cable specially designed for fast, permanent installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Designation\u003c\/td\u003e\n\u003ctd\u003e02YSY (ST) CY 1x2x0,64\/2,55-150 VI KF 40 FR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1000 m; sold by the meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 9.6 kHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.0025 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 38.4 kHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.004 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 4 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.022 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAttenuation at 16 MHz (max)\u003c\/td\u003e\n\u003ctd\u003e0.042 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance (rated)\u003c\/td\u003e\n\u003ctd\u003e150 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance at 9.6 kHz\u003c\/td\u003e\n\u003ctd\u003e270 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance at 38.4 kHz\u003c\/td\u003e\n\u003ctd\u003e185 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance at 3-20 MHz\u003c\/td\u003e\n\u003ctd\u003e150 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance Tolerance at 9.6 kHz\u003c\/td\u003e\n\u003ctd\u003e10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance Tolerance at 38.4 kHz\u003c\/td\u003e\n\u003ctd\u003e10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpedance Tolerance at 3-20 MHz\u003c\/td\u003e\n\u003ctd\u003e10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Resistance per Length (max)\u003c\/td\u003e\n\u003ctd\u003e110 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Resistance per Length (max)\u003c\/td\u003e\n\u003ctd\u003e9.5 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitance per Length at 1 kHz\u003c\/td\u003e\n\u003ctd\u003e28.5 pF\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage (RMS)\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShield Design\u003c\/td\u003e\n\u003ctd\u003eOverlapped aluminum-clad foil, sheathed in a braided screen of tin-plated copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFastConnect Termination\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Conductor Diameter\u003c\/td\u003e\n\u003ctd\u003e0.65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Diameter\u003c\/td\u003e\n\u003ctd\u003e2.55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Sheath Diameter\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Diameter Tolerance\u003c\/td\u003e\n\u003ctd\u003e0.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Insulation Material\u003c\/td\u003e\n\u003ctd\u003epolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Material\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Wire Insulation Color\u003c\/td\u003e\n\u003ctd\u003ered\/green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Sheath Color\u003c\/td\u003e\n\u003ctd\u003eViolet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Single Bend (min)\u003c\/td\u003e\n\u003ctd\u003e37.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBending Radius, Multiple Bends (min)\u003c\/td\u003e\n\u003ctd\u003e75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensile Load (max)\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight per Length\u003c\/td\u003e\n\u003ctd\u003e78 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e87.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-40 to +75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Storage\u003c\/td\u003e\n\u003ctd\u003e-40 to +75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Transport\u003c\/td\u003e\n\u003ctd\u003e-40 to +75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Installation\u003c\/td\u003e\n\u003ctd\u003e-40 to +75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Properties Measured At\u003c\/td\u003e\n\u003ctd\u003e20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire Behavior\u003c\/td\u003e\n\u003ctd\u003eflame resistant according to IEC 60332-3-24 (Category C) and UL 1685 (CSA FT 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurning Behavior Class (EN 13501-6)\u003c\/td\u003e\n\u003ctd\u003eEca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance, Mineral Oil\u003c\/td\u003e\n\u003ctd\u003eoil resistant according to IEC 60811-2-1 (4h\/70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance, Grease\u003c\/td\u003e\n\u003ctd\u003eConditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Resistance, Water\u003c\/td\u003e\n\u003ctd\u003econditional resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUV Resistance\u003c\/td\u003e\n\u003ctd\u003eresistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilicon-Free\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/ETL Listing (300 V)\u003c\/td\u003e\n\u003ctd\u003ec(ETL)us, CMG \/ (ETL)us CL3 \/ Sun Res\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL\/ETL Style (600 V)\u003c\/td\u003e\n\u003ctd\u003ecRUus AWM 21694 AWM I A\/B 60°C 600V FT2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Pollution Resistance (ANSI\/ISA-71.04)\u003c\/td\u003e\n\u003ctd\u003eG3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGWP Total (CO2eq)\u003c\/td\u003e\n\u003ctd\u003e0.92 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGWP Manufacturing (CO2eq)\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGWP Operation (CO2eq)\u003c\/td\u003e\n\u003ctd\u003e0.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGWP End of Life (CO2eq)\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eSold by the meter in 1000 m units, this reel is a bulk stock length for cutting multiple PROFIBUS DP segments to exact site measurements rather than a single continuous run. The same 150 Ω impedance and 0.042 dB\/m attenuation at 16 MHz apply to every cut length, so shorter segments taken from this reel perform identically to the pre-cut 20 m or 50 m variants. Order the shorter fixed-length reels instead when only one short run is needed.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959946633499,"sku":"6XV1830-0EU10","price":1961.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1830-0eu10-profibus-fc-standard-cable-1000m.png?v=1790182076","url":"https:\/\/stoklink.com\/products\/siemens-6xv1830-0eu10-profibus-fc-standard-cable-1000m","provider":"Stoklink","version":"1.0","type":"link"}