{"product_id":"siemens-6xv1830-0et20-profibus-fc-standard-cable-200m","title":"Siemens 6XV1830-0ET20 SIMATIC NET PROFIBUS FC Standard Cable GP 200m Industrial Network Cable","description":"\u003cp\u003eThe Siemens 6XV1830-0ET20 is a 200 m PROFIBUS FC Standard Cable GP, a shielded 2-wire bus cable with 150 Ω characteristic impedance and FastConnect termination for fast on-site assembly. Maximum loop resistance is 110 mΩ\/m and the cable is rated -40 to +75°C, with EAC, CE, and UL approvals for permanent PROFIBUS DP trunk and drop-line installation.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrder Number (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6XV1830-0ET20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169400350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC NET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS FC Standard Cable GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e02YSY (ST) CY 1x2x0,64\/2,55-150 VI KF 40 FR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Electrical Cores\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCharacteristic Impedance (rated)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance at 9.6 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance at 38.4 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e185 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance at 3-20 MHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpedance Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 9.6 kHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0025 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 38.4 kHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.004 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 4 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.022 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation at 16 MHz (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.042 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoop Resistance (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 mΩ\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield Resistance (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9.5 Ω\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacitance at 1 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28.5 pF\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (RMS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShield Design\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverlapped aluminum-clad foil, braided screen of tin-plated copper wires\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFastConnect Termination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInner Conductor Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Insulation Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.55 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInner Sheath Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 mm ± 0.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWire Insulation Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyethylene (PE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInner Sheath Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Wire Insulation Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed \/ Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Sheath Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eViolet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Single Bend (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBending Radius, Multiple Bends (min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e75 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Tensile Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight per Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78 kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight (this length)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14.86 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature (operation \/ storage \/ transport \/ installation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +75 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFire Behavior\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlame resistant per IEC 60332-3-24 (Category C) and UL 1685 (CSA FT 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurning Behavior Class (EN 13501-6)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEca\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOil Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant per IEC 60811-2-1 (4h\/70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Listing (300 V Rating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ec(ETL)us, CMG \/ (ETL)us CL3 \/ Sun Res\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUL\/ETL Style (600 V Rating)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecRUus AWM 21694 AWM I A\/B 60°C 600V FT2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eEAC\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 200 m preferred length covers longer PROFIBUS DP segments in a single continuous run, cutting the number of field splices needed compared with joining shorter reels. FastConnect termination means the 0.65 mm inner conductor accepts insertion-displacement connectors on site rather than a stripped and soldered joint. For a shorter segment, the shorter-length variant in the same cable range avoids unused reel length and reduces installed weight, since this reel already carries 14.86 kg net.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed for permanent PROFIBUS DP fieldbus segments connecting PLCs, remote I\/O, and drives across longer plant runs, where FastConnect on-site termination speeds trunk and drop-line installation. The -40 to +75°C rating and IEC 60332-3-24 flame-resistant sheath suit cable trays and conduit runs in process and factory automation plants.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959944274203,"sku":"6XV1830-0ET20","price":446.87,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6xv1830-0et20-profibus-fc-standard-cable-200m.png?v=1789715152","url":"https:\/\/stoklink.com\/products\/siemens-6xv1830-0et20-profibus-fc-standard-cable-200m","provider":"Stoklink","version":"1.0","type":"link"}