{"product_id":"siemens-6sl3225-0be33-0aa0-pm250-power-module","title":"Siemens 6SL3225-0BE33-0AA0 SINAMICS G120 PM250 FSE 30kW 400V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3225-0BE33-0AA0 is a SINAMICS G120 Power Module PM250 in frame FSE with an integrated Class A EMC filter and energy-recovery capability, rated 380-480V 3AC input at 47-63Hz. Low-overload power is 37.00kW and high-overload power 30.00kW, with a maximum output current of 120.00A and IP20 protection without control unit fitted.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3225-0BE33-0AA0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Designation\u003c\/td\u003e\n\u003ctd\u003ePM250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame size\u003c\/td\u003e\n\u003ctd\u003eFSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V +-10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e70.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e56.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400V IEC \/ 480V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e37.00 kW \/ 50.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e30.00 kW \/ 40.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e75.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e60.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e120.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.99 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.022 m3\/s (0.777 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature LO\u003c\/td\u003e\n\u003ctd\u003e0 ... 40 C (32 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature HO\u003c\/td\u003e\n\u003ctd\u003e0 ... 50 C (32 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e22.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe FSE frame is the largest PM250 in this set, with a 56.00A rated HO input current and 120.00A maximum output current well above the FSD modules' range - use it once continuous torque exceeds what an FSD module supports on a 380-480V supply. Class A filter and energy-recovery capability match the rest of the PM250 line, so braking energy still returns to the supply instead of heating a resistor.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eUsed as the power stage of a SINAMICS G120 drive for large pumps, fans, and hoists on a 380-480V three-phase supply where regenerative braking reduces resistor heat load. Pairs with a matching Control Unit and BOP display.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959468351771,"sku":"6SL3225-0BE33-0AA0","price":5895.38,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3225-0be33-0aa0-pm250-vfd-power-module.png?v=1790181578","url":"https:\/\/stoklink.com\/products\/siemens-6sl3225-0be33-0aa0-pm250-power-module","provider":"Stoklink","version":"1.0","type":"link"}