{"product_id":"siemens-6sl3210-5be27-5uv0-sinamics-v20-7-5kw-vfd","title":"Siemens 6SL3210-5BE27-5UV0 SINAMICS V20 380-480V 7.5kW 16.5A Variable Frequency Drive","description":"\u003cp\u003eThe Siemens 6SL3210-5BE27-5UV0 is a SINAMICS V20 variable frequency drive rated 7.5 kW at 380-480 V three-phase AC input, with 16.5 A rated output current and 150% overload capacity for 60 seconds. It integrates a braking chopper, 4 digital inputs, 2 digital outputs, 2 analog inputs, 1 analog output, and USS\/Modbus RTU fieldbus with a built-in BOP.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6SL3210-5BE27-5UV0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS V20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSINAMICS V20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Phases\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e380-480 V, -15%\/+10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLine Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Power (LO\/HO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.50 kW \/ 10.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated Current (LO\/HO\/IN)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16.50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePulse Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.00 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Frequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0-550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBraking Chopper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2, 1 relay changeover + 1 transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 analog inputs, 1 analog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFieldbus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSS\/Modbus RTU, built-in BOP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Altitude, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40C to 70C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Humidity, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, Shielded\/Unshielded\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 m \/ 50 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDegree of Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20 \/ UL open type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Size D (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 x 207 x 173 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.79 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the unfiltered variant, so it has no built-in EMC filter - add an external filter if the installation needs to meet EN 61800-3 Category C2 conducted-emission limits, or choose the filtered variant instead where filtering must fit in the same enclosure. The 150% overload rating for 60 seconds covers momentary load spikes such as pump startup or conveyor jams without derating the continuous 16.5 A rating, and the integrated braking chopper avoids a separate braking module for regenerative loads such as overhauling loads or fast deceleration ramps.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003ePump and fan speed control, conveyor drives, and general-purpose motor speed control using USS or Modbus RTU on machines that don't need PROFIBUS, plus retrofits needing a compact IP20 panel-mount drive.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959467172123,"sku":"6SL3210-5BE27-5UV0","price":969.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-5be27-5uv0-sinamics-v20-vfd.png?v=1789664385","url":"https:\/\/stoklink.com\/products\/siemens-6sl3210-5be27-5uv0-sinamics-v20-7-5kw-vfd","provider":"Stoklink","version":"1.0","type":"link"}