{"product_id":"siemens-6sl3210-1ph25-2ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PH25-2UL0 SINAMICS G120 PM240-2 37kW\/45kW 500-690V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH25-2UL0 is a SINAMICS G120 PM240-2 power module for 3AC 500-690V supply, rated 37.00 kW at high overload and 45.00 kW at low overload in the FSE frame. A braking chopper is built in, the module ships unfiltered and without a control unit or operator panel, and it is approved from CU firmware V4.7 HF8. It weighs 27.1 kg, carries IP20 protection, and measures 551 x 275 x 237 mm.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH25-2UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e551 x 275 x 237 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (LO)\u003c\/td\u003e\n\u003ctd\u003e50.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input current (HO)\u003c\/td\u003e\n\u003ctd\u003e44.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e690V IEC \/ 600V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e45.00 kW \/ 50.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e37.00 kW \/ 40.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e52.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e42.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e84.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e1.00 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.083 m³\/s (2.931 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation LO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 °C (-4 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation HO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 °C (-4 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e27.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eStepping up from the FSD frame's 37.00 kW low-overload ceiling, this is the entry point of the FSE range in this batch; pick it once the driven load's continuous current exceeds the FSD frame's 70.00 A max. output current. Cooling air requirement rises to 0.083 m³\/s here, so cabinet airflow planning should use this figure rather than the smaller FSD value once frame size changes. The integrated braking chopper still covers occasional regeneration without an external braking module, though sustained regenerative duty on a 45 kW load needs a dedicated resistor sized for it.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959466025243,"sku":"6SL3210-1PH25-2UL0","price":6079.71,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph25-2ul0-pm240-2-vfd-power-module.png?v=1790181488","url":"https:\/\/stoklink.com\/products\/siemens-6sl3210-1ph25-2ul0-pm240-2-vfd-power-module","provider":"Stoklink","version":"1.0","type":"link"}