{"product_id":"siemens-6sl3210-1ph21-4ul0-pm240-2-vfd-power-module","title":"Siemens 6SL3210-1PH21-4UL0 SINAMICS G120 PM240-2 7.5kW\/11kW 500-690V VFD Power Module","description":"\u003cp\u003eThe Siemens 6SL3210-1PH21-4UL0 is a SINAMICS G120 PM240-2 power module for 3AC 500-690V supply, rated 7.50 kW at high overload and 11.00 kW at low overload in the FSD frame. A braking chopper is built in, no input filter is fitted, and the module ships without a control unit or operator panel; it is approved from CU firmware V4.7 HF8. At 17.4 kg and IP20-rated, it fits a 472 x 200 x 237 mm cabinet footprint on 690V industrial distribution.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number (MLFB)\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PH21-4UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4042948668269\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e472 x 200 x 237 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e500 ... 690 V ±10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO)\u003c\/td\u003e\n\u003ctd\u003e14.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO)\u003c\/td\u003e\n\u003ctd\u003e11.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e690V IEC \/ 600V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e11.00 kW \/ 10.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e7.50 kW \/ 7.50 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e22.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e0.32 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.055 m³\/s (1.942 ft³\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation LO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 °C (-4 ... 104 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation HO\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 °C (-4 ... 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 °C (-13 ... 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operation humidity\u003c\/td\u003e\n\u003ctd\u003e95 % RH, condensation not permitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVersion\u003c\/td\u003e\n\u003ctd\u003eScrew-type terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e17.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAt 500-690V, this module connects directly to 690V industrial distribution, unlike the lower-voltage PM240-2 frame sizes built for 200-240V supply. Within the FSD frame, 7.50 kW \/ 11.00 kW is the lowest power point offered in this batch, so it fits pumps and fans whose overload demand stays close to the low-overload rating rather than machines needing sustained torque near the frame's upper current limit. The built-in braking chopper covers occasional regenerative events without an added braking module, screw-type terminals simplify field wiring versus spring-clamp alternatives.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959464550683,"sku":"6SL3210-1PH21-4UL0","price":1753.07,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1ph21-4ul0-pm240-2-vfd-power-module.png?v=1790181463","url":"https:\/\/stoklink.com\/products\/siemens-6sl3210-1ph21-4ul0-pm240-2-vfd-power-module","provider":"Stoklink","version":"1.0","type":"link"}