{"product_id":"siemens-6sl3210-1pe27-5ul0-pm240-2-power-module","title":"Siemens 6SL3210-1PE27-5UL0 SINAMICS G120 PM240-2 400V 37kW IP20 VFD Power Module","description":"\u003cp\u003eThe Siemens SINAMICS G120 PM240-2 power module 6SL3210-1PE27-5UL0 delivers 37 kW low-overload and 30 kW high-overload output at 400 V 3AC, with a built-in braking chopper and an IP20 frame size FSD enclosure. It pairs with a separate control unit to form a modular G120 drive, rated for a 380-480 V line supply at 47-63 Hz.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3210-1PE27-5UL0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS G120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct designation\u003c\/td\u003e\n\u003ctd\u003ePM240-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of phases\u003c\/td\u003e\n\u003ctd\u003e3 AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine voltage\u003c\/td\u003e\n\u003ctd\u003e380 ... 480 V +-10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine frequency\u003c\/td\u003e\n\u003ctd\u003e47 ... 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (LO)\u003c\/td\u003e\n\u003ctd\u003e70.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated current (HO)\u003c\/td\u003e\n\u003ctd\u003e62.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated voltage\u003c\/td\u003e\n\u003ctd\u003e400V IEC \/ 480V NEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (LO)\u003c\/td\u003e\n\u003ctd\u003e37.00 kW \/ 50.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (HO)\u003c\/td\u003e\n\u003ctd\u003e30.00 kW \/ 40.00 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (LO)\u003c\/td\u003e\n\u003ctd\u003e75.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output current (HO)\u003c\/td\u003e\n\u003ctd\u003e60.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. output current\u003c\/td\u003e\n\u003ctd\u003e120.00 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse frequency\u003c\/td\u003e\n\u003ctd\u003e4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, vector control\u003c\/td\u003e\n\u003ctd\u003e0 ... 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency, V\/f control\u003c\/td\u003e\n\u003ctd\u003e0 ... 550 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower loss\u003c\/td\u003e\n\u003ctd\u003e1.01 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.055 m3\/s (1.942 ft3\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,280.84 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (LO)\u003c\/td\u003e\n\u003ctd\u003e-20 ... 40 C (-4 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature (HO)\u003c\/td\u003e\n\u003ctd\u003e-20 ... 50 C (-4 ... 122 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransport temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e-25 ... 55 C (-13 ... 131 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e18.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe LO (low overload) rating of 37 kW covers pump and fan loads that only need 110% overload for 57 s, while the HO (high overload) rating of 30 kW is the figure to size against for conveyor or extrusion loads that need 150% for 3 s. Choose this frame over the lower-current PM240-2 variants in the same series when the driven motor's full-load current exceeds roughly 62 A; the built-in braking chopper removes the need for an external chopper module when a braking resistor is added for fast-stop or overhauling-load applications. The module ships without a control unit, so a CU240 or CU250S-2 control unit and an operator panel must be ordered separately to run the drive.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFits general-purpose 30-37 kW induction motor control in modular G120 drive cabinets: pumps, fans, compressors, and conveyors where the plant standardizes on a separate power module plus control unit architecture rather than a single-housing inverter.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959463960859,"sku":"6SL3210-1PE27-5UL0","price":4402.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3210-1pe27-5ul0-pm240-2-power-module.png?v=1789678502","url":"https:\/\/stoklink.com\/products\/siemens-6sl3210-1pe27-5ul0-pm240-2-power-module","provider":"Stoklink","version":"1.0","type":"link"}