{"product_id":"siemens-6sl3120-2te15-0ad0-double-motor-module","title":"Siemens 6SL3120-2TE15-0AD0 SINAMICS S120 Double Motor Module D-Type 2x5A Drive Module","description":"\u003cp\u003eThe Siemens 6SL3120-2TE15-0AD0 is a SINAMICS S120 Double Motor Module in Bookize D-Type frame, providing two independent axes each rated 5.0 A and 2.7 kW from a 510-720V DC link. It includes Extended Safety Integrated support and the DRIVE-CLiQ cable, with internal air cooling and a 4 kHz pulse frequency.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6SL3120-2TE15-0AD0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSINAMICS S120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame size\u003c\/td\u003e\n\u003ctd\u003eBookize D-Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e3AC 400V, 5A\/5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC link voltage DC\u003c\/td\u003e\n\u003ctd\u003e510 ... 720 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectronics power supply DC\u003c\/td\u003e\n\u003ctd\u003e24 V -15% \/ +20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent demand, max.\u003c\/td\u003e\n\u003ctd\u003e0.90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC-link current Id\u003c\/td\u003e\n\u003ctd\u003e12.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated value IN\u003c\/td\u003e\n\u003ctd\u003e2 x 5.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase load current IH\u003c\/td\u003e\n\u003ctd\u003e2 x 4.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImax\u003c\/td\u003e\n\u003ctd\u003e2 x 15.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBased on IN\u003c\/td\u003e\n\u003ctd\u003e2 x 2.7 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBased on IH\u003c\/td\u003e\n\u003ctd\u003e2 x 2.3 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated pulse frequency\u003c\/td\u003e\n\u003ctd\u003e4.00 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC link busbars\u003c\/td\u003e\n\u003ctd\u003e100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC link capacitance\u003c\/td\u003e\n\u003ctd\u003e220 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for servo control\u003c\/td\u003e\n\u003ctd\u003e650 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for V\/f control\u003c\/td\u003e\n\u003ctd\u003e600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput frequency for vector control\u003c\/td\u003e\n\u003ctd\u003e300 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation altitude (without derating)\u003c\/td\u003e\n\u003ctd\u003e1,000 m (3,281 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eInternal air cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling air requirement\u003c\/td\u003e\n\u003ctd\u003e0.009 m3\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0 ... 40 C (32 ... 104 F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor cross-section\u003c\/td\u003e\n\u003ctd\u003e1.5 ... 6 mm2 (16 ... 10 AWG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielded cable length\u003c\/td\u003e\n\u003ctd\u003e50 m (164 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e4.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe D-Type frame packs two independent 5.0 A axes (2.7 kW on IN, 2.3 kW on IH each) into one module footprint, the choice when driving two smaller motors from a single DC-link connection instead of the C-Type Single Motor Module's one 60 A axis. Each axis is commanded independently by the Control Unit over DRIVE-CLiQ, and the 650 Hz servo \/ 600 Hz V\/f \/ 300 Hz vector output-frequency limits match the Single Motor Module family. Pick this module when the application needs two lower-power axes rather than one high-current axis.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eFits multi-axis SINAMICS S120 configurations, such as handling or packaging machines, where two motors each draw up to 5.0 A from a shared DC link and Line Module. Conductor cross-section runs 1.5 to 6 mm2 with up to 50 m of shielded motor cable per axis.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960715862299,"sku":"6SL3120-2TE15-0AD0","price":1792.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6sl3120-2te15-0ad0-double-motor-module-drive-module.png?v=1789714218","url":"https:\/\/stoklink.com\/products\/siemens-6sl3120-2te15-0ad0-double-motor-module","provider":"Stoklink","version":"1.0","type":"link"}