{"product_id":"siemens-6nh3112-0bb00-0xx0-rtu3011c-telecontrol-module","title":"Siemens 6NH3112-0BB00-0XX0 SIMATIC RTU3000C RTU3011C 8DI\/8DO\/4AI GNSS Telecontrol Module","description":"\u003cp\u003eThe Siemens 6NH3112-0BB00-0XX0 SIMATIC RTU3011C is a compact, battery- or solar-powered remote terminal unit with 8 DI, 8 DO and 4 AI onboard, an Industrial Ethernet port and GNSS positioning. It speaks DNP3, IEC 60870-5-104, SINAUT ST7 or MQTT for telecontrol and cloud reporting, and configures through its built-in webserver rather than dedicated engineering software.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6NH3112-0BB00-0XX0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC RTU3000C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4047623165651\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type Designation\u003c\/td\u003e\n\u003ctd\u003eRTU3011C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003eStandby (Sleep) mode, Actualization mode, Communication mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing \u0026amp; Mounting\u003c\/td\u003e\n\u003ctd\u003eCompact module, 130 x 100 x 75 mm (W x H x D), 35 mm top-hat DIN rail or wall mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class IP\u003c\/td\u003e\n\u003ctd\u003eIP20; IP68 with optional protective housing accessory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e1x Industrial Ethernet, RJ45 port, 10 ... 100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Connection\u003c\/td\u003e\n\u003ctd\u003e5-pole pluggable terminal block, 1 connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Card Slot\u003c\/td\u003e\n\u003ctd\u003e1 slot; SD 1.0, SD 1.1, SDHC or Siemens SMC, max. 32 GiB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNSS Antenna Connection\u003c\/td\u003e\n\u003ctd\u003eActive GNSS antenna\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e8, pluggable screw terminal block, open-drain transistor or switch, 2-wire; 2 of the 8 usable as counter inputs (min. pulse 0.1 ms, max. 5000 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e8, pluggable screw terminal block; 4x bistable relay (2-wire) + 4x solid-state relay; output current 300 mA (solid-state 60 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4, pluggable screw terminal block, 2\/3\/4-wire, 12-bit A\/D; parameterizable for 0\/4-20 mA, 0-5\/10 V or Pt1000 -80 ... +140 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWireless \/ Mobile Connectivity\u003c\/td\u003e\n\u003ctd\u003eVia external IP-based router (no onboard modem)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003eDC, 10.8 ... 28.8 V external (12 ... 24 V range); output 12 V or 24 V DC for external devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGNSS Antenna Supply\u003c\/td\u003e\n\u003ctd\u003e3.8 V nominal (3.575 V at 5 mA, 3.35 V at 10 mA, 3.125 V at 15 mA), max. 15 mA output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption, External 24V DC\u003c\/td\u003e\n\u003ctd\u003eStandby 14 mA, update 35 mA, communication 55 mA (typical, without connected consumers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption, Battery 7.2V\u003c\/td\u003e\n\u003ctd\u003eStandby 0.28 mA, update 71 mA, communication 125 mA (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss, External 24V DC\u003c\/td\u003e\n\u003ctd\u003eStandby 0.34 W, update 0.85 W, communication 1.25 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss, Battery 7.2V\u003c\/td\u003e\n\u003ctd\u003eStandby 0.002 W, update 0.51 W, communication 0.9 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Operation\u003c\/td\u003e\n\u003ctd\u003e-40 ... +60 °C vertical mounting; -40 ... +70 °C horizontal busbar arrangement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Temperature, Storage \/ Transport\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity, Max\u003c\/td\u003e\n\u003ctd\u003e95% at 30 °C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCloud Connectivity\u003c\/td\u003e\n\u003ctd\u003eMQTT; trigger management, time stamping, buffered message frame memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e45 program block types, up to 48 configurable program blocks, 48 digital and 24 analog bit memories max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIT Functions\u003c\/td\u003e\n\u003ctd\u003eFTP client (1 connection, 12-entry buffer); email client (1 connection, 20 addresses \/ 10 user groups max., 20 free texts max. of 160 characters, 12-entry buffer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTelecontrol\u003c\/td\u003e\n\u003ctd\u003eSubstation-capable; connects to IEC 60870-5-104, DNP3, SINAUT ST7cc\/sc or TeleControl Server Basic control centers; permanent or demand-oriented connection; max. 256 KiB user data per station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoadable Protocols\u003c\/td\u003e\n\u003ctd\u003eDNP3, IEC 60870-5, SINAUT ST7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection-Loss Buffering\u003c\/td\u003e\n\u003ctd\u003eApprox. 5,000 telegrams (IEC 60870), 10,900 (DNP3), 7,700 (SINAUT ST7), 10,900 (TeleControl Server Basic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTeleservice\u003c\/td\u003e\n\u003ctd\u003eRemote firmware update, remote configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eNo configuration software required, via integrated webserver; SIMATIC PDM gateway via Modbus TCP or HART-IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eWeb-based diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVPN Security\u003c\/td\u003e\n\u003ctd\u003eOpenVPN client, AES-128\/AES-256 encryption, certificate-based authentication, SHA-256 hashing, 2 possible connections (1 simultaneous productive connection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOther Security Functions\u003c\/td\u003e\n\u003ctd\u003ePassword protection for web applications, teleservice and VPN; encrypted data transmission; switch-off of unused services; SysLog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Functions\u003c\/td\u003e\n\u003ctd\u003eNTP support; hardware real-time clock with battery backup, accuracy max. 1.8 s\/day; sync from NTP, GPS, control center, PC or manual setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePosition Detection\u003c\/td\u003e\n\u003ctd\u003eGPS position detection with position data passed to the control center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications, TED-Confirmed\u003c\/td\u003e\n\u003ctd\u003eCE, UKCA, cULus, RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003ecULus\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eULHazLoc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 10.8 to 28.8 V DC external input plus a 7.2 V battery mode means this RTU keeps logging and buffering telegrams, up to roughly 10,900 for DNP3 or TeleControl Server Basic, through mains outages without a separate UPS. Two of the eight digital inputs double as 5 kHz counter inputs, so flow or pulse metering does not need a separate counter module. Choose the loadable protocol, DNP3, IEC 60870-5-104, SINAUT ST7 or MQTT, to match the control center already in use, since the unit runs one protocol stack at a time rather than several concurrently; check GNSS national approvals for the installation country before deployment.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959824146715,"sku":"6NH3112-0BB00-0XX0","price":1224.88,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6nh3112-0bb00-0xx0-rtu3011c-telecontrol-module.png?v=1790181126","url":"https:\/\/stoklink.com\/products\/siemens-6nh3112-0bb00-0xx0-rtu3011c-telecontrol-module","provider":"Stoklink","version":"1.0","type":"link"}