{"product_id":"siemens-6gk5552-0ar00-2hr2-scalance-xr552-12m-rear-l3","title":"Siemens 6GK5552-0AR00-2HR2 SCALANCE XR552-12M 16-Port Managed PoE Switch Rear Ports L3 Integrated","description":"\u003cp\u003eThe Siemens SCALANCE XR552-12M (6GK5552-0AR00-2HR2) is a managed 19-inch rack Ethernet switch with 12 hot-swappable media-module ports and 4x 10 Gbit\/s SFP+ uplinks, supporting up to 180 W of PoE across its rear-facing ports. Layer 3 IP routing is integrated, so static and dynamic routing with RIPv2, OSPFv2 and VRRP run without an add-on license, and a C-PLUG ships included.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5552-0AR00-2HR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR552\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169252522\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXR552-12M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10, 100, 1000 Mbit\/s electrical; 10 Gbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMedia Module Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12, electrical \/ electrical PoE \/ optical, hot-swappable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSFP+ Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4, 1000\/10000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConsole Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, RJ11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemovable Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC-PLUG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Power, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 W per port, 180 W total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC, range 19.2-28.8 V, 34.08 W, 12.5 A max., 4-pole terminal block, fuse F15A\/125V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 ... +60 °C, integral replaceable fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, Storage\/Transport\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40 ... +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity, Max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% at 25 °C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 3U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e449 mm x 130.8 mm x 305 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Outlet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable outlet at rear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRouting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLayer 3 integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRouting Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStatic and dynamic IP routing (IPv4\/IPv6), RIPv2, RIPnG, OSPFv2, OSPFv3, VRRP, VRRP for IPv6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. VLANs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET Conformity Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Ethernet Telegram Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9216 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, MIB, Telnet, TFTP, FTP, BOOTP, GMRP, DCP, LLDP, SNMP v1\/v2\/v3, IGMP snooping\/querier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTP, RSTP, RSTP+, MSTP, MRP with redundancy manager, MRP-I, HRP with redundancy manager and standby, PRP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x RADIUS, broadcast\/multicast\/unicast limiter, broadcast blocking, SSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Sync\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNTP, SNTP, SICLOCK support, IEEE 1588\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePort diagnostics, packet size\/type statistics, error statistics, SysLog, I\u0026amp;M0\/I\u0026amp;M1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe rear-port layout suits cabinets wired from behind, and Layer 3 routing is already integrated — static and dynamic IP routing with RIPv2, OSPFv2 and VRRP work without a separate KEY-PLUG XR-500 license, unlike the Layer-3-prepared variant of this switch. That makes it the direct choice where the switch must route between VLANs or subnets at the aggregation layer instead of only switching. The 4x SFP+ ports carry the 10 Gbit\/s uplinks while the 12 media-module ports deliver up to 180 W of PoE to field devices.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eLayer 3 aggregation switch for PROFINET networks that route between VLANs or subnets at the switch itself, mounted in cabinets wired from the rear, with PoE for field devices.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959803535643,"sku":"6GK5552-0AR00-2HR2","price":15671.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5552-0ar00-2hr2-scalance-xr552-12m-rear-l3.png?v=1789825364","url":"https:\/\/stoklink.com\/products\/siemens-6gk5552-0ar00-2hr2-scalance-xr552-12m-rear-l3","provider":"Stoklink","version":"1.0","type":"link"}