{"product_id":"siemens-6gk5528-0aa00-2hr2-scalance-xr528-6m","title":"Siemens 6GK5528-0AA00-2HR2 SCALANCE XR528-6M 6-Slot Modular PoE 10G Rear 24V DC Industrial Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5528-0AA00-2HR2 SCALANCE XR528-6M is a modular managed Industrial Ethernet switch with 4 fixed SFP+ 10 Gbit\/s uplinks and 6 media module slots for up to 24 further electrical, PoE or optical ports, powered from a 24 V DC supply and rated up to 180 W of Power-over-Ethernet. Ports face the rear of the 2U 19-inch rack enclosure, and it adds IEEE 1588 time synchronization alongside its integrated redundancy manager.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Order No (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5528-0AA00-2HR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR528\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXR528-6M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLayer 3 Routing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePrepared (KEY-PLUG XR-500 required to activate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\/100\/1000 Mbit\/s; 10 Gbit\/s on SFP+ uplinks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFixed Uplink Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x SFP+ (10 Gbit\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMedia Module Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6, each a 4-port module (electrical RJ45, PoE, or optical SFP\/ST-BFOC\/SC, multimode or single-mode) - up to 24 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Usable Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 28 (4 fixed SFP+ plus up to 24 via media modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoE Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 12 ports can deliver Power-over-Ethernet depending on media modules fitted; 30 W max per port, 180 W total budget\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort Orientation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC (19.2-28.8 V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss (base unit)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e11.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF 15 A \/ 125 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...+60 °C (with replaceable integral fan)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\/Transport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 95% at 25 °C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 2U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e449 x 87.2 x 305 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Outlet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, SNMP v1\/v2\/v3 with MIB support, configuration with STEP 7, port and multiport mirroring, CoS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, FTP, BOOTP, GMRP, DCP, LLDP, IGMP snooping\/querier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVLAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePort-based, protocol-based, IP-based; up to 255 VLANs (255 dynamic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRP with redundancy manager, MRP-I (LC mode), HRP with redundancy manager and standby, RSTP\/RSTP+\/MSTP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRouting Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRIPv2, RIPng, OSPFv2, OSPFv3, VRRP, VRRP for IPv6 (Layer 3 routing requires the optional KEY-PLUG XR-500 license)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), SSH, broadcast\/multicast\/unicast limiter, broadcast blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePort diagnostics, packet size and type statistics, error statistics, SysLog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNTP, SNTP, SICLOCK support, IEEE 1588 time synchronization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO device, conformity class B, max. telegram length 9216 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4019169233187\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eUKEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eUL HazLoc\u003c\/li\u003e\n\u003cli\u003eCCC\u003c\/li\u003e\n\u003cli\u003eFM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThe 6 media module slots let this unit mix electrical, PoE and optical ports on one chassis instead of forcing a fixed port layout, so a panel builder can populate only the media types a project needs and add modules later. The 180 W PoE budget across up to 12 ports covers IP cameras or wireless access points fed straight from the switch, no separate injector. IEEE 1588 support makes this the variant to pick where devices downstream need sub-millisecond time synchronization rather than NTP\/SNTP alone. This is the rear-port version; choose the front-port variant where the cabinet is cabled from the front. Layer 3 routing is prepared but inactive until a KEY-PLUG XR-500 is fitted.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959800029467,"sku":"6GK5528-0AA00-2HR2","price":11145.28,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5528-0aa00-2hr2-scalance-xr528-6m-industrial-ethernet-switch.png?v=1789825269","url":"https:\/\/stoklink.com\/products\/siemens-6gk5528-0aa00-2hr2-scalance-xr528-6m","provider":"Stoklink","version":"1.0","type":"link"}