{"product_id":"siemens-6gk5524-8gs00-3ar2-scalance-xr524-8c","title":"Siemens 6GK5524-8GS00-3AR2 SCALANCE XR524-8C 24-Port L3-Ready 230V AC Industrial Ethernet Switch","description":"\u003cp\u003eThe Siemens 6GK5524-8GS00-3AR2 SCALANCE XR524-8C is a Layer 3-ready managed Industrial Ethernet switch with 24 RJ45 10\/100\/1000 Mbit\/s ports, including 8 combo ports for SFP transceivers, powered from a single 230 V AC supply. It runs as a PROFINET IO device with conformity class B diagnostics and supports office-grade redundancy and management protocols (RSTP, VLAN, IGMP) in a 1U 19-inch rack enclosure rated IP20.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Order No (MLFB)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6GK5524-8GS00-3AR2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCALANCE XR524\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eXR524-8C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLayer 3 Routing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReady (KEY-PLUG XR-500 required to activate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfer Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\/100\/1000 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRJ45 Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 (10\/100\/1000 Mbit\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCombo Ports (RJ45\/SFP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Usable Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 V AC (90-264 V range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Current Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.15 A \/ 250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundant Supply Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal present (this variant ships with a single supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25...+60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\/Transport Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40...+85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eup to 95% at 25 °C, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19-inch rack, 1U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e449 x 44 x 305 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Outlet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignaling Contact\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-pole terminal block, 24 V DC \/ 0.1 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManagement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCLI, web-based management, SNMP v1\/v2\/v3 with MIB support, configuration with STEP 7, port and multiport mirroring, CoS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTelnet, TFTP, FTP, BOOTP, GMRP, DCP, LLDP, IGMP snooping\/querier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVLAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePort-based, protocol-based, IP-based; up to 255 VLANs (255 dynamic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMRP with redundancy manager, MRP-I (LC mode), HRP with redundancy manager and standby, RSTP\/RSTP+\/MSTP, LACP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRouting Protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRIPv2, RIPng, OSPFv2, OSPFv3, VRRP, VRRP for IPv6 (Layer 3 routing requires the optional KEY-PLUG XR-500 license)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSecurity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.1x (RADIUS), SSH, broadcast\/multicast\/unicast limiter, broadcast blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePort diagnostics, packet size and type statistics, error statistics, SysLog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime Synchronization\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNTP, SNTP, SICLOCK support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePROFINET\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO device, conformity class B, max. telegram length 9216 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Interference Emission\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-4 (Class A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Immunity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL 60950-1, CSA C22.2 No. 213-M1987\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEAN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4047622195147\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003cli\u003eUKCA\u003c\/li\u003e\n\u003cli\u003eKC\u003c\/li\u003e\n\u003cli\u003eRCM\u003c\/li\u003e\n\u003cli\u003eRoHS\u003c\/li\u003e\n\u003cli\u003eEPD\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eThis is the single-supply variant of the XR524-8C: one 230 V AC feed with a spare power terminal, no second supply installed. Choose it for cabinets on a single reliable AC circuit; pick the dual-supply variant when the switch sits on a critical PROFINET segment that must stay up through a single feed loss. Layer 3 routing (RIPv2, OSPFv2, VRRP) is present in firmware but stays inactive until a KEY-PLUG XR-500 is fitted, so budget for the license if the site needs inter-VLAN routing rather than pure Layer 2 switching.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53959796162843,"sku":"6GK5524-8GS00-3AR2","price":7112.17,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6gk5524-8gs00-3ar2-scalance-xr524-8c-industrial-ethernet-switch.png?v=1789825213","url":"https:\/\/stoklink.com\/products\/siemens-6gk5524-8gs00-3ar2-scalance-xr524-8c","provider":"Stoklink","version":"1.0","type":"link"}