{"product_id":"siemens-6es7547-1jf00-0ab0-cm-8xio-link-master-module","title":"Siemens 6ES7547-1JF00-0AB0 SIMATIC S7-1500 CM 8xIO-Link 8-Port IO-Link Master Communication Module","description":"\u003cp\u003eThe Siemens 6ES7547-1JF00-0AB0 is a SIMATIC S7-1500 CM 8xIO-Link communication module, an 8-port IO-Link V1.1 master supporting IO-Link protocols 1.0 and 1.1 with up to 8 ports simultaneously controllable. It runs on 24 V DC, 20.4 to 28.8 V, delivers 1 A per port with 4 A total current per module, and mounts directly on the S7-1500 rail.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7547-1JF00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM 8xIO-Link\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirmware Version\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eV1.0.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO-Link, digital input (DI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage, permissible range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4 to 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Consumption, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA, without load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIO-Link Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8, all simultaneously controllable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIO-Link Protocol Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIO-Link 1.0, IO-Link 1.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCycle Time, min.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Data, Input per Port, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e33 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Data, Input per Module, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Data, Output per Port, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcess Data, Output per Module, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e240 byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Parameter Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kbyte per port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaster Backup\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration without S7-PCT\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length, unshielded, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePort Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eType A; Type B with 24 V DC via external terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current, rated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 A per port, 4 A total current per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, per channel, electronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption from Backplane Bus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 x 147 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, horizontal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 60 degC, observe derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature, vertical\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30 to 40 degC, observe derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test), between channels and backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS7-1500 mounting rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngineering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 TIA Portal V15.1 with HSP 274 or higher\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight (shipping)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.302 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCountry of Origin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eAll 8 IO-Link ports are simultaneously controllable at a 2 ms minimum cycle time, so a fully populated module updates every port without a scan-time penalty for using more channels. Each port carries 1 A, 4 A total per module, enough for most IO-Link sensors and small pneumatic valve terminals but a figure worth checking against actuator inrush current on multi-actuator ports. Master backup stores IO-Link device configurations on the module itself, so a failed sensor can be swapped without re-downloading parameters from the CPU. Ports left unused for IO-Link communication can be parameterized as plain 24 V digital inputs instead.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eConnecting IO-Link V1.1 sensors and actuators, photoelectric sensors, pressure switches, and small valve terminals directly to the S7-1500 backplane without a separate fieldbus gateway, with per-port diagnostics for wire break, short-circuit, and supply voltage monitoring.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960656126235,"sku":"6ES7547-1JF00-0AB0","price":795.91,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7547-1jf00-0ab0-cm-8xio-link-master-module.png?v=1789798303","url":"https:\/\/stoklink.com\/products\/siemens-6es7547-1jf00-0ab0-cm-8xio-link-master-module","provider":"Stoklink","version":"1.0","type":"link"}