{"product_id":"siemens-6es7526-1bh00-0ab0-f-di-16x24vdc-profisafe","title":"Siemens 6ES7526-1BH00-0AB0 SIMATIC ET 200MP F-DI 16x24VDC PROFIsafe SIL3 Fail-safe PLC I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7526-1BH00-0AB0 is a SIMATIC ET 200MP fail-safe digital input module (F-DI 16x24VDC PROFIsafe) with sixteen 24 V DC safety inputs rated up to Performance Level e per ISO 13849-1 and SIL 3 per IEC 61508. It mounts on the ET 200MP backplane in a 35 mm module width and carries safety data over PROFIsafe into the F-CPU's safety program.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU \/ Order No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6ES7526-1BH00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500 \/ ET 200MP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF-DI 16x24VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16, sourcing\/sinking (P-reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V, permissible range 19.2 - 28.8 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage (DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated 24 V; signal 1: +15 to +30 V, signal 0: -30 to +5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEncoder Supply Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4, max. 300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePerformance Level (ISO 13849-1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSIL (IEC 61508)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePFDavg (SIL3, low demand)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5.00E-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePFH (SIL3, high demand)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1.00E-09 1\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Test Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e707 V DC (type test)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAddress Space\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9 byte in \/ 5 byte out (S7-300\/400F CPU: 8\/4 byte)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 m shielded \/ 500 m unshielded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption (backplane bus)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Loss, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0...60 degC horizontal \/ 0...40 degC vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (W x H x D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35 x 147 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight, approx.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eCertifications \u0026amp; Standards\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eISO 13849-1 PLe\u003c\/li\u003e\n\u003cli\u003eIEC 61508 SIL 3\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003e16 fail-safe channels on one 35 mm module cover a full safety zone (E-stops, guard doors, light curtains) without stacking multiple smaller F-DI modules, which keeps the ET 200MP rack shorter and cuts engineering points. The PLe \/ SIL 3 rating and PFH below 1.00E-09 1\/h qualify it for the highest safety category most machine-safety applications require, so pick a lower-channel-count F-DI variant only when the panel has fewer safety signals to save rack width.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eWiring emergency-stop circuits, safety door interlocks, light curtains, and two-hand controls into a SIMATIC S7-1500 \/ ET 200MP safety program over PROFIsafe, in machine safety and process-safety installations that require SIL 3 \/ PLe certification.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960651669787,"sku":"6ES7526-1BH00-0AB0","price":909.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7526-1bh00-0ab0-f-di-16x24vdc-fail-safe-plc-io-module.png?v=1789663492","url":"https:\/\/stoklink.com\/products\/siemens-6es7526-1bh00-0ab0-f-di-16x24vdc-profisafe","provider":"Stoklink","version":"1.0","type":"link"}