{"product_id":"siemens-6es7522-5ff00-0ab0-dq-8x230vac-2a-st","title":"Siemens 6ES7522-5FF00-0AB0 SIMATIC S7-1500 DQ 8x230VAC\/2A ST 8-Channel Triac PLC I\/O Module","description":"\u003cp\u003eThe Siemens 6ES7522-5FF00-0AB0 is a SIMATIC S7-1500 digital output module, type DQ 8x230VAC\/2A ST, with 8 Triac outputs rated 120\/230 V AC and 2 A per channel. Each channel carries a built-in 6.3 A slow-blow fuse, and total module current is limited to 10 A. Front connectors are ordered separately.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e6ES7522-5FF00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEAN\u003c\/td\u003e\n\u003ctd\u003e4025515079873\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type designation\u003c\/td\u003e\n\u003ctd\u003eDQ 8x230 V AC\/2A ST (triac)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFirmware version\u003c\/td\u003e\n\u003ctd\u003eV2.3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of digital outputs\u003c\/td\u003e\n\u003ctd\u003e8, Triac type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage, rated\u003c\/td\u003e\n\u003ctd\u003e120\/230 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput current, rated (signal 1)\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching capacity, resistive load, max.\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching capacity, lamp load, max.\u003c\/td\u003e\n\u003ctd\u003e50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in fuse\u003c\/td\u003e\n\u003ctd\u003e6.3 A slow-blow, per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal current, per module, max.\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching frequency, resistive load, max.\u003c\/td\u003e\n\u003ctd\u003e10 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable length, shielded \/ unshielded, max.\u003c\/td\u003e\n\u003ctd\u003e1 000 m \/ 600 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotential separation channels, groups of\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation tested with\u003c\/td\u003e\n\u003ctd\u003e3 100 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature, operation\u003c\/td\u003e\n\u003ctd\u003e-25 to 60 degrees C (horizontal), -25 to 40 degrees C (vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e35 x 147 x 129 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight, approx.\u003c\/td\u003e\n\u003ctd\u003e290 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch2\u003eSelection Notes\u003c\/h2\u003e\u003cp\u003eEach of the 8 channels is isolated individually (groups of 1), so a fault on one output does not affect the others, unlike modules that isolate in larger groups. The 6.3 A slow-blow fuse per channel is sized above the 2 A rated output to absorb inrush from lamp or small-motor loads without nuisance tripping, and two outputs can be paralleled for redundant control of a single load. The 10 Hz maximum switching frequency on resistive loads and 0.5 Hz on inductive loads mark this as a standard switching module, not suited to high-frequency PWM-style control; use a DC or solid-state output module for that. Front connectors (screw-terminal or push-in) are not included.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003eSwitching 230 V AC loads such as contactor coils, indicator lamps, and solenoid valves directly from an S7-1500 station, including redundant shutdown paths using the paralleled-output function.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":53960649900315,"sku":"6ES7522-5FF00-0AB0","price":307.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0903\/7722\/4475\/files\/siemens-6es7522-5ff00-0ab0-dq-8x230vac-2a-st-module.png?v=1789714765","url":"https:\/\/stoklink.com\/products\/siemens-6es7522-5ff00-0ab0-dq-8x230vac-2a-st","provider":"Stoklink","version":"1.0","type":"link"}